Maintenance / servicing
49
BA.10A.CNY.001.01.10.GB
For assembly of the impeller and casing read section on at
page 50.
7. Insert the O-rings 0412.03 into the hexagon
head sterile screws 0918.00.
Fig. 59
Hexagon head sterile screw
8. Fix the seal cover 0471.00 to the discharge cas-
ing 0107.00 by means of the hexagon head ster-
ile screw 0918.00.
9. For tightening the hexagon head sterile screw
0918.00: Use socket wrench with insert (HILGE
assembly tool kit, fig. 81).
Torque M6: 8 Nm
Fig. 60
Seal cover