List of tools (in alphabetical order)
Tool
Figure
Intended Purpose
Material Number
GEA Aseptomag AG
Protective gloves,
heat-resistant
Fig.14
Remove/fit hard valve
seat seals
--
Shut-off valve Ø 6 mm
Fig.15
Inspection of metal
bellows
9999.10091
10.5
Prior to disassembly
Prerequisite:
•
Make sure that while work is being performed on the open valve no process is
in operation in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse, and also depressurize them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
®
Disassembly has been prepared.
10.6
Disassembling and Assembling the Valve
10.6.1 Disassembling the Valve
Tools required:
•
Hex socket key
Caution!
Danger of injury due to spring force being released
You can sustain injuries to your fingers when you put your hand into a valve
if the valve has not been moved to the open position beforehand.
► Before starting any work, bring the valve to the "open" position.
► Wear protective gloves for all work.
► Always exercise caution and prudence.
Maintenance
Prior to disassembly
430BAL013317EN_1
34
11.03.2019
Содержание Aseptomag AMV