– 11 –
Remove Unbalance Switch
WARNING: The exposed electrical connector
for the unbalance switch carries 120 volts.
Be sure power to washer is disconnected.
Failure to comply can cause injury or death.
1. Disconnect unbalance switch wire harness
connectors.
2. Remove 2 screws and the unbalance switch
from the washer.
Remove Water Valve
1. Remove hoses from water valve.
2. Remove 2 screws (A) and metal cover from
water valve.
3. Disconnect water valve wire harness connec-
tors.
4. Remove screw (B) and small panel from under
hose connections.
5. Remove remaining 4 screws (C) and water
valve from washer.
6. Remove water valve from rinse hose.
Remove Detergent Assembly
1. Remove water valve.
2. Remove 2 screws from bottom of detergent
case.
3. Remove rinse hose.
Remove Pump Assembly
1. Lay washer on left side.
2. Disconnect both wire harness connectors.
3. Remove 3 hose clips and hoses.
4. Remove 3 screws (A) holding pump assembly
to washer base.
5. Supporting pump assembly, remove 2 screws
(B) and pump assembly from left-side outer
case.
Note: The pump assembly has a cleanout access
that unscrews to remove foreign objects
from the pump. Symptoms of a clogged pump
include no pumping and noise when pumping.
GEA00163
B
A
GEA00160
C
A
A
A
A
A
A
GEA00154
GEA00149
B
B
B
B
Cleanout
Cleanout
GEA00326