– 48 –
5. Disconnect the thermistor wire harness.
6. Disconnect the stator and Hall sensor wire
harnesses from the motor.
7. Remove the Phillips-head screw that attaches
the ground wire to the motor shield.
8. Remove the Phillips-head screw from the motor
harness support, then slide the support up and
pull it out from the motor shield.
9. Remove the dispenser vent hose from the outer
tub:
a. Squeeze the clamp and slide it back.
b. Carefully break the vent hose loose by
inserting a small fl at blade screwdriver
under the hose to break the seal.
c. Remove the hose.
Note: When installing the dispenser vent hose,
ensure the notch cutout is engaged with the right-
side tab on the tub inlet.
10. Remove the dispenser from the front and
left side braces, then remove the dispenser
outlet hose from the dispenser. (See
Dispenser
Assembly
.)
11. Place the dispenser assembly over the left rear
corner of the washer.
12. Remove the three 10-mm hex head bolts
and washers that attach each of the 2
counterweights to the front of the outer tub.
13. Remove the water level sensor hose from the
water level sensor. (See
Water Level Sensor
.)
Dispenser
Assembly
(Continued Next Page)
Disconnect
Disconnect
Motor Harness
Support
Motor Shield
Notch
Tab
Dispenser Vent Hose