Description

The ESL supervised smoke alarms are self-diagnostic Learn Mode
wireless sensors with 319.5 MHz transmitters that use photoelectric
technology with a self contained sounder, a low battery annunciator,
status LED, and integrated fixed temperature and rate-of-rise heat
sensor. Each unit has a base tamper switch, is part of a residential
security/fire alarm system, and communicates with the system control
panel.

Transmitted Signal Outputs

•Alarm

•Tamper

•Test

•Low battery

•Trouble

•Supervisory

Programming

This section describes the basic steps for programming (learning) the
unit into panel memory. For complete programming instructions, refer
to the specific panel installation instructions.

1. Separate the unit from the mounting base by turning the unit

counter clockwise about 15 degrees.

2 . Slide the battery cover away from the unit to unsnap it and lift it

off. See Figure 2.

3. Observing polarity, insert the 2 lithium batteries (included) into the

battery compartment and replace the battery cover.

4. Attach the unit to the mounting base by lining up the alignment tab

(see Figure 3) on the unit with the alignment arrow on the mounting
base, then put the unit on the base and turn it clockwise about 15
degrees. The unit should snap into place.

5. Put the panel into installer programming mode (refer to your panel

installation instructions) and proceed to learning/enrolling sensors.

6. When prompted by the panel to learn/enroll the sensor, trip the

tamper by separating the unit from the mounting base. See Step 1.

7 . Attach the unit to the mounting base. See Step 4.

8. Exit from installer programming mode.

Verify Programming and Unit-to-Panel
RF Communication

Before mounting, verify that the desired unit location provides good RF
communication to the panel.

1 . Put the panel into Dealer Sensor Test mode (refer to the specific

panel installation instructions).

2 . Take the unit to the desired mounting location.

3 . Press and hold the unit Test/Silence button for 4 seconds. The unit

transmits a test signal.

4. Listen for the appropriate response from system sirens to determine

signal integrity from the unit to the panel (refer to the specific panel
installation instructions).

5. Exit from Dealer Sensor Test mode.

Mounting

Mounting hardware is included (screws and anchors), however you may
need different hardware depending on the installation.

1 . Separate the unit from the mounting base. See Programming Step 1.

2 . Place the mounting base on the mounting surface at the desired

location and mark the mounting holes using a pencil.

3. Secure the mounting base to the surface.

4 . Attach the unit to the mounting base. See Programming  Step 4.

Sensor Test

The system and sensor test verifies good communication between the unit
and receiver/panel. The sensor test should be performed weekly.

1 . Put the panel into Sensor Test mode (refer to the specific panel

installation instructions).

2 . Press and hold the Test/Silence button for 4 seconds. The unit

transmits a test signal.*

*Holding the Test/Silence button for 20 seconds will cause the unit to
send a signal through to a central station.

3 . Listen for the appropriate response from system sirens (refer to the

specific panel installation instructions).

4 . After testing all units, exit from Sensor Test mode.

Smoke Test

The smoke test verifies that the unit activates when detecting smoke, that
the transmitted signal is received by the receiver/panel, and that the panel
reports the alarm to the central monitoring station. The smoke test
should be performed annually.

1. Contact the central monitoring station to alert them you are testing

the system and they should not dispatch authorities.

2 . Activate the unit using one of the following two methods:

Method 1 Hold a smoldering punk or cotton wick close to the unit and
direct the smoke into the smoke entry openings for about 20 seconds.

Method 2 Use Smoke! in a can

®

 and follow the directions on the can.

Once activated, the transmitter LED turns on, the built-in sounder
emits a temporal 3 pattern, and the unit transmits an alarm signal. The
panel then processes the alarm signal and reports the alarm condition
to the central station.

 4300 Series

Wireless Smoke Detector

Wireless

Required smoke alarms

Additional alarms required for new construction

1

Dining Room

2

Kitchen

3

Living Room

4

Bedroom

5

TV Room

6

Basement

6

A

1

2

3

4

4

4

B

5

1

2

3

4

4

4

C

4

4

1

3

6

Détecteurs de fumée requis

 

Détecteurs supplémentaires nécessaires

dans les nouvelles pièces

1

Salle à manger

2

Cuisine

3

Salle de séjour

4

Chambre à coucher

5

Salle de télévision

6

Sous-sol

Содержание TX-6010-01-1

Страница 1: ...ical chamber latch 3 Optical chamber 4 Alignment arrows 5 Alarm cap 1 VOYANT DEL 2 Capteur de température 3 Bouton de Test Arrêt 4 Évent du résonateur 1 Compartiment de la pile 1 Touche d alignement 2 Flèche d alignement 1 Support optique 2 Verrou de la chambre optique 3 Chambre optique 4 Flèches d alignement 5 Couvercle de l alarme Détecteurs de fumée sans fil contrôlé ESL Manuel TX 6010 01 1 4 2...

Страница 2: ... instructions 5 Exit from Dealer Sensor Test mode Mounting Mounting hardware is included screws and anchors however you may need different hardware depending on the installation 1 Separate the unit from the mounting base See Programming Step 1 2 Place the mounting base on the mounting surface at the desired location and mark the mounting holes using a pencil 3 Secure the mounting base to the surfa...

Страница 3: ...ium batteries into the battery compartment and replace the cover 5 Reattach the unit to the mounting base See Programming Step 4 6 Test the system Cleaning Clean the cover with a dry or damp water cloth as needed to keep it free from dust and dirt When necessary clean the interior and replace the optical chamber part 211 as follows 1 Disconnect the alarm notification appliances 2 Remove the unit f...

Страница 4: ... role of the AHJ At government installations the commanding officer or department official may be the AHJ General Guidelines Before mounting units program learn them into panel memory and perform a sensor test from the unit s intended location to ensure good RF communication to the panel Locate units in environmentally controlled areas where the temperature range is between 40 and 100 F 4 4 and 37...

Страница 5: ... alarm may be blocked or reflected by metal objects Adjacent devices or systems using radio frequency signals may interfere with the operation of this alarm Test the system weekly to ensure signals are transmitted and received properly Closed or partially closed doors and distance can block or reduce the alarm sound from this alarm This alarm is not designed for the hearing impaired Smoke alarms c...

Страница 6: ...ion à l étape 4 Test de détection Le test de détection et de système vérifie l état de la communication entre l appareil et le récepteur panneau Le test de détection doit être effectué une fois par semaine 1 Mettre le panneau en mode Test de détection Sensor Test se reporter aux instructions d installation du panneau 2 Appuyer sur le bouton Test Arrêt et le maintenir enfoncé pendant 4 secondes L a...

Страница 7: ...e couvercle de l alarme dans l appareil et tourner d environ 15 degrés dans le sens des aiguilles d une montre Il devrait s engager fermement en place 9 En respectant la bonne polarité remplacer les piles et le couvercle du compartiment de la pile 10 Fixer de nouveau l appareil dans le socle de fixation Voir Programmation à l étape 4 11 Tester la sensibilité et reconnecter les appareils d avertiss...

Страница 8: ...sécurité publique est primordiale ces autorités peuvent être un ministère fédéral provincial une autorité régionale municipale ou encore un responsable tel que le chef des pompiers le chef du service des incendies le chef du bureau de prévention des incendies ministère de la main d oeuvre ou de la santé un inspeceur en électricité ou toute autre personne possédant un pouvoir juridique Aux fins d a...

Страница 9: ... tout autre endroit d entreposage est propice aux incendies Utiliser avec soin les matières combustibles et les appareils électriques et uniquement selon leurs utilisations spécifiques Ne pas surcharger les prises de courant Ne pas entreposer d explosifs ou des matières à combustion rapide dans votre résidence Même après la mise en place de précautions un incendie peut éclater Soyez prêt En cas d ...

Страница 10: ... afin de décrire la nature de la défectuosité Lorsqu une alarme sous garantie doit être retournée une attention particulière doit être apportée lors de son emballage car GE Security n effectue aucune réparation pour les appareils qui ont subi des dommages à cause d un emballage inadéquat La garantie ci dessus remplace toutes les garanties expresses ou implicites de qualité marchande et d aptitude ...

Отзывы: