at 192.168.10.40 The IP address of the receiver. Once these settings are saved on their respective web pages the
SymNet will begin sending streaming video (once requested) and the SymDec 4 will begin receiving streaming
video.
All the settings on the Advanced Streaming settings must match between the sender and the receiver.
In this configuration both the SymDec-1 and SymDec 4 are able to receive a video stream from the SymNet or
SymVeo IP Camera.
Figure 15. SymDec 4 setup as receiver and SymNet setup as sender
Streaming Settings for UDP multicast
Figure 16
illustrates streaming settings for a UDP multicast from the SymNet to the default multicast address.
The default multicast address is 230 for the first field and the balance being the unit’s current IP address.
The SymDec 4 is setup as a receiver in
Normal
mode with the
Receiver Cam Map IP
address set at
192.168.10.20 (The IP address of the sender) and
Use default Multicast Address
checked. The SymNet is setup
as a sender with the mulitcast address set at 230.168.10.20. Once these settings are saved on their respective
web pages the SymNet will begin sending multicasting video (once requested) and the SymDec 4 will begin
receiving streaming video.