GE RN328HSA Скачать руководство пользователя страница 12

12

D. Recirculating (non-vented ductless–

JN327 and RN328, and optional on
JV347, JV348 and JV367 models only)

• 

Use the hood as a template and mark the locations 

on the cabinet for the electrical wiring and keyhole
screw slots.

• 

Since the hood is to be recirculated (not to be vented

outside), do not cut out any vent openings in the wall
or cabinet bottom.

Installation Instructions

Wood shims 

(recessed-bottom cabinets only–shims must be a
minimum of 3/8

thick and cut to fit the width 

of the inner recessed cabinet bottom)

Cabinet front

Center line

Electrical access hole

(in wall)

Hood mounting screws (4)

Horizontal duct 
access hole

Cabinet
bottom

13

3

4

(30

hood)

16

3

4

(36

hood)

1

1

4

1

2

3

3

4

5

1

4

5

1

4

7

3

4

13

3

4

(30

hood)

16

3

4

(36

hood)

C. Outside rear exhaust 

(Horizontal duct–3

1

4

x 10

Rectangular)

• 

Use the diagram or the hood as a template and 

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

RUN WIRES

Run the electrical wires through the wall or 
cabinet according to National Electrical Code 
and applicable local codes.

NOTE: 

DO NOT turn the power on until

installation is complete.

13

CUT HOLES

Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4

extra

toward the front of the cabinet so you can move the
duct freely when installing the hood. It may also ease
installation by cutting the hole 10

1

2

instead of 10

.

12

MARK HOLES

Select the vent option that your installation will
require and proceed to that section:

Hood mounting screws (4)

13

3

4

(30

hood)

16

3

4

(36

hood)

13

3

4

(30

hood)

16

3

4

(36

hood)

Cabinet front

Center

line

Electrical access hole 
(in cabinet bottom)

Wood shims 

(recessed-bottom cabinets
only–shims must be a
minimum of 3/8

thick

and cut to fit the width 
of the inner recessed
cabinet bottom)

Vertical duct 

access hole

9

5

8

1

3

8

1

1

4

7

3

4

3

3

4

1

2

A. Outside top exhaust 

(Vertical duct–3

1

4

x 10

Rectangular)

• 

Use the diagram or the hood as a template and

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

B.Outside top exhaust (Vertical duct–7

Round)

• 

Use the diagram or the hood as a template and 

mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

Hood mounting screws (4)

13

3

4

(30

hood)

16

3

4

(36

hood)

13

3

4

(30

hood)

16

3

4

(36

hood)

Cabinet front

Center

line

Electrical access
hole 

(in cabinet bottom)

Wood shims 

(recessed-bottom cabinets
only–shims must be a minimum
of 3/8

thick and cut to fit the

width of the inner recessed
cabinet bottom)

Access 
hole for 7

round duct

9

5

8

1

3

8

1

1

4

7

3

4

5

3

4

Cabinet
bottom

8

DIA.

HOLE

Cabinet Bottom

11

5

1

4

5

1

4

Содержание RN328HSA

Страница 1: ...Consumer Support Back Cover Warranty 15 JN327 Recirculation only JV338 Vent options only JV347 Vent Recirculation options JV348 Vent Recirculation options JV367 Vent Recirculation options RN328 Recir...

Страница 2: ...her and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based...

Страница 3: ...l endroit o il a commenc 3 Vous avez d j appel les pompiers 4 Vous combattez les flammes en tournant le dos une sortie Bas sur l ouvrage intitul Kitchen Fire Safety Tips publi par la NFPA AVERTISSEMEN...

Страница 4: ...e vent hood Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood The efficiency of your hood depends on a clean filter Frequency of cleaning...

Страница 5: ...the top opening Gently push the cover up and press the sides to fit the side prongs into the side openings Release and the cover will lock in position Hood Light The charcoal filter cannot be cleaned...

Страница 6: ...irect route and with as few elbows as possible This ensures clear venting of exhaust and helps prevent blockages Also make sure dampers swing freely and nothing is blocking the ducts Elbows transition...

Страница 7: ...LENGTH DUCT EQUIVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 53 Ft x Ft wall cap 39 ft w o with damper x Ft damper 6 Round 72 Ft x Ft roof cap 6 Round 3 Ft x Ft to 31 4 x 10 rect transition 6 Rou...

Страница 8: ...an the customer repair or replacement must be made by arrangement between customer and installer DAMAGE SHIPMENT INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES This range hood is for installation ov...

Страница 9: ...VENT OPTION Determine the vent option that your installation will require and that is available for your model from the below choices 1 IMPORTANT If the hood is to be installed in a recirculating non...

Страница 10: ...e long side of the baffle should be inside the hood REMOVE WIRING COVER Remove the wiring cover from inside the hood Set the cover and its mounting screw aside Wiring cover REMOVE WIRING KNOCKOUT Remo...

Страница 11: ...t ears in preparation for later attachment of the 7 duct 8 9 Installation Instructions NOTE The exhaust adaptor damper can be installed up to 1 inch on either side of the hood center to accommodate of...

Страница 12: ...al duct cut out 3 4 extra toward the front of the cabinet so you can move the duct freely when installing the hood It may also ease installation by cutting the hole 101 2 instead of 10 12 MARK HOLES S...

Страница 13: ...y excess length of cord and tie away with a suitable tape or tie Cabinet 73 4 3 prong wall outlet if using cord connection 11 4 13 4 dia clearance hole for optional power supply location C L FEED IN W...

Страница 14: ...adjust as needed The fan does not work but the lights do Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the s...

Страница 15: ...or you may be required to bring the product to an Authorized GE Service Location for service In Alaska the warranty excludes the cost of shipping or service calls to your home Some states do not allo...

Страница 16: ...hat are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your...