background image

ZONELINE SERIES – DIRECT ELECTRICAL CONNECTION

Installation Instructions

1. REMOVE ROOM FRONT

Remove the room cabinet by pulling it out at the bottom 
to release it (1); then lift it up to clear the rail along the 
unit top (2).

4.  ATTACH WIRING USING A SUB-BASE 

AND CHASEWAY (sold separately)

1.

   Remove cover adjacent to the knockout from sub-

base and retain. Remove the rectangular knockout at 

the right end of the sub-base. 

2.   

Wiring is placed between the two halves of the 

chaseway. Observe the orientation of the chaseway.

3.

   Align the screw holes and secure the halves together 

using two screws provided with chaseway.

4.  

 Slide the upper end of chaseway with wiring protruding 

into rectangular knockout opening in the junction box. Be 

sure chaseway side flanges are on the inside of the box. 

Drive one screw (provided with chaseway) through the 

junction box bottom into the chaseway side flange. 

5. 

  Insert lower end of chaseway into rectangular hole in 

sub-base and slide to right into the rectangular knockout 

making sure chaseway side flanges are inside the sub-

base. Route wire toward the center of the sub-base. 

Drive one screw (provided with sub-base/chaseway kit) 

through the sub-base slotted hole into chaseway side 

flange hole.

6. 

  Reinstall sub-base cover.

2. REMOVE JUNCTION BOX COVER

Remove 2 junction box cover screws and retain. 
Remove cover and retain.

3.  REMOVE JUNCTION BOX KNOCKOUT

For sub-base/chaseway installation: 

Remove 

rectangular knockout from junction box base.

Rectangular
Chaseway 
Knockout

5. INSTALL JUNCTION BOX COVER

1.   

Carefully tuck all wires and connections back 

inside the junction box. Be sure there are no loose 

connections or stray uninsulated wires exposed.

2.   

Align junction box cover ensuring mating tabs base 

are inserted into slots on cover.  Drive screws 

securing cover in place.

3.   

Check to ensure all wires are inside junction box and 

no wires are pinched between cover and base.

4.   

Turn power 

back on to the 

installed unit and 

check operation.

5.  

  Replace the 

Zoneline front 

cabinet.

Wiring

Chaseway cover

Chaseway

Knockout

Sub-base

Cover

2