GE PVWS930 and Скачать руководство пользователя страница 11

Installation Instructions

1 1

PARTS  PROVIDED

  - 

Continued

1  Ft  =  0.3  m

1”  =  2.5  cm

• Hood  canopy  with  internal  blower,  grease  filters  and

lights  already  installed

• Glass  vapour  catcher

• Duct  covers

• Duct  Cover  support  bracket

• Transition  (may  be  already  installed)

• Hardware  Packet:

Note: the hardware packet contains several fittings material.

For model PVWG936, consider what is listed below ONLY:

• Allen  Wrench

• Lower  support  bracket  x  2  (to  attach  the  hood

canopy)

• Rubber  tape  (for  glass  vapour  catcher)

• Bushes  x  4  (for  glass  vapour  catcher)

• 6  x  20  screws  x  4  (for  glass  vapour  catcher)

• Template

• Use,  Care  and  Installation  Guide

• 10  x  60  drywall  anchors  x  2  (To  attach  duct  cover

support  bracket)

•6 x 80 screws x 6 +washers x 6 (2 To attach duct cover

support  bracket  +  4  to  attach  the  hood  canopy)

•3,5 x 9,5 screws x 14 (2 to attach the tran 4 to

attach  the  duct  cover  +  8  to  attach  the  lower  support

brackets)

MODEL  PVWG936

DUCTING OPTIONS AND EXAMPLES

Closely  follow  the  instructions  set  out  in  this  manual.

All  responsibility,  for  any  eventual  inconveniences,

damages  or  fires  caused  by  not  complying  with  the

instructions  in  this  manual,  is  declined.

Venting Methods

The  hood  is  equipped  with  a  transition  B  for  discharge

of  fumes  to  the  outside 

(Ducting  version)

.

Models  PVWS930/936  and  PVWT936:  Minimum  Duct

Size  (Ducting/Ductless  version):  5"  Round  Pipe.
Models  PVWG936  and  PVIG940:  Minimum  Duct  Size

(Ducting/Ductless  version):  6"  Round  Pipe.

• Hood  canopy  with  internal  blower,  grease  filter  and

lights  already  installed

• Glass  vapour  catcher

• Duct  covers

• Chimney  structure

• Transition  (may  be  already  installed)

• Use,  Care  and  Installation  Guide

• Hardware  Packet:

Note: the hardware packet contains several fittings material.

For model PVIG940, consider what is listed below ONLY:

• Allen  Wrench

• Rubber  tape  (for  glass  vapour  catcher)

• Bushes  x  4  (for  glass  vapour  catcher)

• 6  x  20  screws  x  4  (for  glass  vapour  catcher)

• Template

•6 x 80 screws x 4 + washers x 4(To attach the chimney

structure  to  the  ceiling)

•3,5 x 9,5 screws x 16 (8 to assemble the str 4 to

attach the duct  2 to attach the tran 2 to

attach  the  junction  cover  (may  be  already  intsalled))

• 8  x  16  screws  x  4  (to  attach  the  canopy  to  the  structure).

MODEL  PVIG940

Ducted Version

Pipe

Pipe

Sidewall  Cap

with  Gravity

Damper

Pipe

Roof Pitch w/Flashing and Cap

Ducted Version

Roof Pitch w/Flashing and Cap

Preparation

Do  not  cut  a  joist  or  stud  unless  absolutely  necessary.  If

a  joist  or  stud  must  be  cut,  then  a  supporting  frame

must  be  constructed.
Fittings  material  is  provided  to  secure  the  hood  to  most

types  of  walls/ceilings.
However,  a  qualified  technician  must  verify  suitability  of

the  materials  in  accordance  with  the  type  of

wall/ceiling.
Before  making  cutouts,  make  sure  there  is  proper

clearance  within  the  ceiling  or  wall  for  exhaust  vent.
Hood  installation  height  above  cooktop  is  the  users

preference.  The  lower  the  hood  is  above  the  cooktop,

the  more  efficient  the  capturing  of  cooking  odors,

grease  and  smoke.
Min. installation height from the range top to the bottom of the
hood is 30” it a gas range is used  or 24” to 30” if an electric range 
is used. 
These Hoods are  not recommended to be used over indoor 
grills.

.

Check  your  ceiling  height  and  the  hood  height

maximum  before  you  select  your  hood.

Models  PVWS930/936,  PVWT936

and  PVWG936

Model  PVIG940

Содержание PVWS930 and

Страница 1: ...ces 5 Installation Instructions 7 16 Troubleshooting Tips 18 Consumer Support Consumer Support Back Cover Product Registration 19 20 Warranty 21 Write the model and serial numbers here Model _________...

Страница 2: ...vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING To reduce the risk of fire or electric shock DO NOT use this fan with any solid state speed contro...

Страница 3: ...TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B...

Страница 4: ...ded with a storage device which counts the number of hours of operation and which regulates the lighting up of the coal filter saturation LEDS For the correct operation of this device it is important...

Страница 5: ...ry completely before reinstalling them To clean the hood surface For general cleaning operations rub the external part of the hood made of glass using soapy water or household cleaning products rinsin...

Страница 6: ...re cool before cleaning or servicing any part of the vent hood Unscrew the lamp diffusers Remove the blown lamp and replace it with a new 20 Watt max 12 Volt halogen lamp with a G 4 cap Follow the ins...

Страница 7: ...TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION CAUTION WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be...

Страница 8: ...IMENSIONS 1 Ft 0 3 m 1 2 5 cm 12 13 4 2 5 15 7 24 8 PVWG936 MODEL W D H PVWT936 PVWG936 PVIG940 12 13 4 2 5 15 7 24 8 PVIG940 PVWS930 93 30 36 19 3 33 3 45 7 15 75 T 36 19 3 38 6 55 5 15 75 36 19 7 33...

Страница 9: ...cturer s guidelines and safety standards such as those published by NFPA and ASHRAE DUCT FITTINGS Using a smaller diameter duct size will reduce performance Actual length of straight duct plus duct fi...

Страница 10: ...Kit Kit 02282 Models PVWS930 936 PVWT936 Carbon Filter Filtrating Deflector Changes Hood from Venting to Filtrating Kit 02283 Models PVWG936 PVIG940 Carbon Filter Filtrating Deflector Rounded transit...

Страница 11: ...nsition may be already installed Use Care and Installation Guide Hardware Packet Note the hardware packet contains several fittings material For model PVIG940 consider what is listed below ONLY Allen...

Страница 12: ...before and fasten the template to the wall using adhesive tape as indicate above at point 3 6 x 80 Models PVWS930 936 and PVWT936 A Centerline B Mounting Hook Location C Fastener Locations D Mounting...

Страница 13: ...ews D Leveling Screws Model PVWG936 6 x 80 17 Install the transition at the top of the hood in case it has been removed Models PVWS930 936 and PVWT936 6 x 80 3 5 x 9 5 Model PVWG936 3 5 x 9 5 18 Conne...

Страница 14: ...d secure junction box cover 20 Check all light bulbs to make sure they are secure in their sockets Turn power On in service panel Check lights and blower operation 21 Install filters 22 Install duct c...

Страница 15: ...eep it Cut the dry wall of the ceiling and remove it Install some wooden strips of suitable length 2 x 4 between the joists to create the assembly points of the chimney flue Use the template for the d...

Страница 16: ...ther with the telescopic structure and fasten them together using 4 screws M8 x 16 Then you can carry out the electrical connection consult Step 19 of WALL INSTALLATION instructions on previous page 1...

Страница 17: ...17 Notes www GEAppliances ca Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning...

Страница 18: ...ot need to call for service P r o b l e m P o s s i b l e Causes What To Do Fan does not operate A fuse may be blown or a Replace fuse or reset circuit breaker when the switch is on circuit breaker tr...

Страница 19: ...ERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR R SIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et e...

Страница 20: ...O NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND R G TELEPHONE T L PHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHET UN CONTRAT DE SE...

Страница 21: ...ple your receipt here Proof of the original purchase date is needed to obtain service under the warranty Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Clean...

Страница 22: ...a Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every da...

Страница 23: ......

Страница 24: ......

Отзывы: