1 0

OPTIONAL ACCESSORIES

1  Ft  =  0.3  m

1”  =  2.5  cm

TOOLS  AND  MATERIALS  REQUIRED

(NOT  SUPPLIED)

Additional  Materials:

•120V 60Hz. 15 or 20 Amp, 2 wire with ground.

P

roperly grounded branch circuit.

•Strain relief for junction box.

7”  round  metal  duct  or  3¼”  x  12”  rectangular  duct,  length

to  suit  installation.

Duct  tape

¼”  pivoting  hex  socket

Pencil  and

tape  measure

Spirit  level

Phillips  and

Flat  blade  screwdrivers

Electric  drill  with

1

/

8

”  and 

3

/

8

”  bits

cUL  Listed  Wire  nuts

Hammer

Safety  glasses

Metal  snips

Flashlight

Pliers

Wire  Cutter/Stripper

Saber  saw  or  Key  Hole  Saw

Ladder

Allen  Wrench

Kit  02279     Model  PVIG940

extension chimney (H)   

Kit  02280     Model  PVWG936

extension chimney (H)

Kit  02281    Models PVWS930/936

extension chimney (H)

Ductless  Recirculating  Kit

Kit  02282    Models  PVWS930/936,  PVWT936

Carbon  Filter  +  Filtrating  Deflector:

Changes  Hood  from  Venting  to 

Filtrating

Kit  02283    Models PVWG936 , PVIG940

Carbon  Filter  +  Filtrating  Deflector  +

Rounded transition:  Changes  Hood  from 
Venting  to Filtrating

PARTS PROVIDED

• Hood  canopy  with  internal  blower,  grease  filters  and

lights  already  installed

• Duct  covers
• Duct  Cover  support  bracket
• Transition  (may  be  already  installed)
• Hardware  Packet:
Note:  the  hardware  packet  contains  several  fittings  material.
For  models  PVWS930,  PVWS936  and  PVWT936,  consider
what  is  listed  below  ONLY:

• Hook  with  leveling  screws  x  2
• Template
• Use,  Care  and  Installation  Guide
• 10  x  60  drywall  anchors  x  2  (To  attach  duct  cover

support  bracket)

• 6  x  80  screws  x  8  +  washers  x  8  (2  To  attach  duct  cover

support  bracket  +  6  to  attach  the  hood  canopy)

• 3,5  x  9,5  screws  x  6  (2  to  attach  the  transition  +  4  to

attach  the  duct  cover)

MODELS  PVWS930,  PVWS936  AND  PVWT936

MIN 34.8”

MAX 48.4”

MIN 36.4”

MAX 52”

MIN 36.4”

MAX 52”

Содержание PVWS930 and

Страница 1: ...ces 5 Installation Instructions 7 16 Troubleshooting Tips 18 Consumer Support Consumer Support Back Cover Product Registration 19 20 Warranty 21 Write the model and serial numbers here Model _________...

Страница 2: ...vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING To reduce the risk of fire or electric shock DO NOT use this fan with any solid state speed contro...

Страница 3: ...TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B...

Страница 4: ...ded with a storage device which counts the number of hours of operation and which regulates the lighting up of the coal filter saturation LEDS For the correct operation of this device it is important...

Страница 5: ...ry completely before reinstalling them To clean the hood surface For general cleaning operations rub the external part of the hood made of glass using soapy water or household cleaning products rinsin...

Страница 6: ...re cool before cleaning or servicing any part of the vent hood Unscrew the lamp diffusers Remove the blown lamp and replace it with a new 20 Watt max 12 Volt halogen lamp with a G 4 cap Follow the ins...

Страница 7: ...TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION CAUTION WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be...

Страница 8: ...IMENSIONS 1 Ft 0 3 m 1 2 5 cm 12 13 4 2 5 15 7 24 8 PVWG936 MODEL W D H PVWT936 PVWG936 PVIG940 12 13 4 2 5 15 7 24 8 PVIG940 PVWS930 93 30 36 19 3 33 3 45 7 15 75 T 36 19 3 38 6 55 5 15 75 36 19 7 33...

Страница 9: ...cturer s guidelines and safety standards such as those published by NFPA and ASHRAE DUCT FITTINGS Using a smaller diameter duct size will reduce performance Actual length of straight duct plus duct fi...

Страница 10: ...Kit Kit 02282 Models PVWS930 936 PVWT936 Carbon Filter Filtrating Deflector Changes Hood from Venting to Filtrating Kit 02283 Models PVWG936 PVIG940 Carbon Filter Filtrating Deflector Rounded transit...

Страница 11: ...nsition may be already installed Use Care and Installation Guide Hardware Packet Note the hardware packet contains several fittings material For model PVIG940 consider what is listed below ONLY Allen...

Страница 12: ...before and fasten the template to the wall using adhesive tape as indicate above at point 3 6 x 80 Models PVWS930 936 and PVWT936 A Centerline B Mounting Hook Location C Fastener Locations D Mounting...

Страница 13: ...ews D Leveling Screws Model PVWG936 6 x 80 17 Install the transition at the top of the hood in case it has been removed Models PVWS930 936 and PVWT936 6 x 80 3 5 x 9 5 Model PVWG936 3 5 x 9 5 18 Conne...

Страница 14: ...d secure junction box cover 20 Check all light bulbs to make sure they are secure in their sockets Turn power On in service panel Check lights and blower operation 21 Install filters 22 Install duct c...

Страница 15: ...eep it Cut the dry wall of the ceiling and remove it Install some wooden strips of suitable length 2 x 4 between the joists to create the assembly points of the chimney flue Use the template for the d...

Страница 16: ...ther with the telescopic structure and fasten them together using 4 screws M8 x 16 Then you can carry out the electrical connection consult Step 19 of WALL INSTALLATION instructions on previous page 1...

Страница 17: ...17 Notes www GEAppliances ca Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning...

Страница 18: ...ot need to call for service P r o b l e m P o s s i b l e Causes What To Do Fan does not operate A fuse may be blown or a Replace fuse or reset circuit breaker when the switch is on circuit breaker tr...

Страница 19: ...ERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR R SIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et e...

Страница 20: ...O NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND R G TELEPHONE T L PHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHET UN CONTRAT DE SE...

Страница 21: ...ple your receipt here Proof of the original purchase date is needed to obtain service under the warranty Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Clean...

Страница 22: ...a Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every da...

Страница 23: ......

Страница 24: ......

Отзывы: