VII. ADJUSTMENT
7.3
OLP (OVER LOAD PROTECTOR)
7.3.1
Definition of OLP
i.
OLP (Over Load Protector) is attached
to hermetic Compressor and protects
motor by cutting off current in
Compressor motor by Bimetal in the
OLP in case of overrising temperature.
ii.
When over voltage flows to
Compressor motor, Bimetal works by
heating the heater inside OLP, and
OLP protects motor by cutting off
current which flows to compressor
motor.
7.3.2
Role of OLP
i.
OLP is attached to hermetic
Compressor used to refrigerator and
show case and prevents motor coil
from being started in the Compressor.
iii. Do not turn the Adjust Screw of OLP
in any way for normal operation of
OLP (Composition and Connection
Diagram of OLP)