![GE Protimeter MMS Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/ge/protimeter-mms/protimeter-mms_instruction-manual_128429020.webp)
Protimeter MMS Moisture Measurement System
Page 17
6 Technical Specifications
Weights and Dimensions
Protimeter MMS Kit
(BLD5800): 2.5 lb (1.1 kg),
9 in. x 7.5 in. x 3.5 in. (230 mm x 190 mm x 90 mm)
Protimeter MMS Instrument
(POL5800JC): 10.58 oz (300 g),
7 in. x 2.75 in. x 1.9 in. (180 mm x 70 mm x 49 mm)
Hygrostick Probe
(POL4750): 2 in. long x 0.3 in. (50 mm long x 8 mm),
optimal clearance hole 12 mm dia. (when used with compression sleeve
to measure ERH in solid material)
Humistick Probe
(POL7750-2): 2.5 in. long x 0.5 in. (65 mm long x 12 mm)
Power
2 x AA batteries
Measurement Ranges
Moisture Meter
Search Mode:
0-1000 relative scale, nominal depth of
measurement 0.6 in. (15 mm),
tolerance ±10 relative scale
Measure Mode:
8-29 %WME, 30-100 relative scale in
saturated material
Hygrostick Probe
Measurement Range:
30-100 %rh, 32 to 122°F (-10 to 50°C)
Tolerance (nominal):
30-40 %rh, ±3 %rh @68°F (20°C)
41-98 %rh, ±2 %rh @68°F (20°C)
32 to 122°F (-10 to 50°C), ±0.6°F (±0.3°C)
Humistick Probe
Measurement Range:
0-100 %rh, 32 to 122°F (-10 to 50°C)
Tolerance (nominal):
0-10 %rh, ±3 %rh @68-86°F (20-30°C)
10-90 %rh, ±2 %rh @68-86°F (20-30°C)
90-100 %rh, ±3 %rh @68-86°F (20-30°C)
32 to 122°F (-10 to 50°C), ±0.6°F (±0.3°C)
Surface Temperature Sensor: 32 to 122°F (-10 to 50°C), ±0.6°F (±0.3°C)