Installation Instructions
ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS*
Model #
Voltage
Frequency
KW
PP989 120/240V
60Hz
9.1KW
120/208V
60Hz
6.9KW
* For reference only. Verify with product rating plate.
16
BEFORE MAKING ELECTRICAL
CONNECTIONS
Note to Electrician:
The power leads supplied with this
appliance are UL-recognized for connection to large gauge
household wiring.
The insulation of these leads is rated at temperatures much
higher than the temperature rating of household wiring. The
current carrying capacity of a conductor is governed by the
wire gauge and also the temperature rating of the insulation
around the wire.
Aluminum Wiring –
WARNING:
IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING
TO THE COPPER LEADS CAN RESULT IN SERIOUS
PROBLEMS.
Attach copper wires to aluminum wiring using special
connectors designed and UL-listed for joining copper
to aluminum. Follow the connector manufacturer’s
recommended procedure closely.
Service Loop –
Leave a loop in the wires to the cooktop so
that the cooktop can be lifted 12 inches without having to
disconnect the wiring.
Electrical installation kit
JXCK89
may be ordered separately
and includes all the parts necessary to connect the cooktop
to typical rough-in wiring.
17
INSTALL 3/4” FLEXIBLE CONDUIT
Remove the screws holding the
wire compartment cover and
remove the cover.
Feed the power
supply leads through
the conduit; be sure to
leave enough length
to properly connect
these leads to the
cooktop power leads.
Thread the leads
through an anti-short
bushing and firmly
seat the bushing in
the end of the conduit.
Feed the leads
through the hole in the
wire compartment.
As local codes permit
purchase a listed
conduit connector
suitable for the size
conduit. Insert the
conduit through the
connector and attach
it to the cover. Allow
enough slack to easily
attach the wires to the
cooktop.
NOTE:
Do not install
the cooktop without
a listed conduit
connector. The
conduit connector
should be installed
before reinstalling the
wiring cover.
When complete,
reinstall the wire
compartment cover.
Rating Plate
Power Supply
Leads
Anti-Short
Bushing
Conduit
Bushing (Fully Seated)
Conduit
Connector
Conduit