background image

TOOLS YOU WILL NEED

FOR YOUR SAFETY:

All rough-in and spacing dimensions must be
met for safe use of your range. On ranges
with storage drawers electricity can be
disconnected at the outlet without moving
the range if the outlet is in the preferred
location (remove storage drawer).

To reduce the risk of burns or fire when
reaching over hot surface elements, cabinet
storage space above the cooktop should be
avoided. If cabinet storage space is to be
provided above the cooktop, the risk can 
be reduced by installing a range hood that
sticks out at least 5” beyond the front of the
cabinets. Cabinets installed above a cooktop
must be no deeper than 13”

.

Be sure your appliance is properly installed
and grounded by a qualified technician.

Make sure the cabinets and wall coverings
around the range can withstand the temperatures
(up to 200°F.) generated by the range.

2

Installation Instructions

PREPARE TO INSTALL THE RANGE

MATERIALS YOU MAY NEED

Anchor Sleeves

Lag Bolts

(For Anti-Tip Bracket Mounted 

on Concrete Floors Only)

3-Wire Cord

4‘ Long

4-Wire Cord  

OR

4‘ Long

(UL Approved 40 AMP)

Adjustable Wrench

Level

1/4” Nut Driver

Phillips Screwdriver

Drill with 1/8” Bit

Pencil

Safety Glasses

Tape Measure

Pliers

Flat-blade

Screwdriver

PARTS INCLUDED

Anti-Tip Bracket Kit

REMOVE SHIPPING MATERIALS

Remove packaging materials. Failure to
remove packaging materials could result
in damage to the appliance.

1

Squeeze Connector

(For Conduit

Installations Only)

Tin Snips

Содержание Profile JB900TKWW

Страница 1: ...ng the installation switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locke...

Страница 2: ...t be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician Make sure the cabinets and wall coverings around the range can withstand the temperatures up...

Страница 3: ...VE THE COOKTOP Make sure the wall covering countertop flooring and cabinets around the range can withstand the heat up to 200 F generated by the range Allow 30 minimum clearance between surface units...

Страница 4: ...CAL REQUIREMENTS CAUTION For personal safety do not use an extension cord with this appliance Remove house fuse or open circuit breaker before beginning installation This appliance must be supplied wi...

Страница 5: ...train relief they can be removed for better fit NOTE Do not install the power cord without a strain relief The strain relief bracket should be installed before reinstalling the rear range wiring cover...

Страница 6: ...ral is connected to the center lower position of the terminal block Tighten screws securely into the terminal block Skip to Step 8 and proceed with the installation E D C B A 5 3 WIRE POWER CORD INSTA...

Страница 7: ...ocal codes Skip to Step 8 and proceed with the installation B A 6 4 WIRE CONDUIT INSTALLATION Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate an...

Страница 8: ...liquids or from the range itself 9 Typical installation of anti tip bracket attachment to wall Bracket Screw must enter wood or metal Wall plate REPLACE THE WIRE COVER Replace the wire cover on the ra...

Страница 9: ...door and drawer are parallel to each other and that both operate smoothly If they do not see the Owner s Manual for proper replacement Check to make sure that the rear leveling leg is fully inserted...

Страница 10: ...10 Notes...

Страница 11: ...11 Notes...

Страница 12: ...12 Printed in the United States...