– 9 –
5. • Guide the wires into the duct as you place
the blower unit back into the opening.
• Secure the blower unit to the oven with the
screw from Step 2.
CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are
not pinched.
6. Replace the blower plate in the same position
as before, under its retaining flange, and
attach it with the screws.
7. Proceed to the PREPARATION OF THE
TOP CABINET section.
C. RECIRCULATION
(Non-Vented, Ductless)
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want
to save them for possible future use. (You must
use the Charcoal Filter Kit. See your Owner's
Manual for kit number.)
1. Remove and save the screws that hold the
blower plate to the oven.
2. • Slide the blower plate back from under its
retaining flange and lift it off.
• Remove and save the screw that holds the
blower motor to the oven.
3. Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
• Roll the blower unit so that the fan
blades are facing towards the front
of the oven.
• The wires should be routed in the grooves of
the motor frame.
Blower Plate
BEFORE:
Fan Blade Openings Facing Up
Blower
Unit
AFTER:
Fan Blade Openings Facing Front of Oven
Blower
Unit
Grooves
Grooves
Retaining
Flange
Retaining
Flange