Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
PRE-INSTALLATION CHECKLIST
GROUNDING INSTRUCTIONS
IMPORTANT—(Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
This warming drawer must be supplied with 120V,
60Hz, and connected to an individual, properly
grounded branch circuit, and protected by a 15 or
20 amp circuit breaker or time delay fuse.
■
A properly grounded 3-prong receptacle should
be located within reach of the drawer’s 56" long
power cord.
■ Locate the receptacle in an adjacent cabinet.
—
within 42” of the right side or,
—
within 16” of the left side or
—
A recessed receptacle may be located on
the right side of the cutout, 7” maximum from
the back of the cabinet. In this location, the
excess power cord should be coiled and taped
to the right side of the unit.
IMPORTANT—(Please read carefully)
The power cord of this appliance is equipped with a
3-prong (grounding) plug that mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock. The customer should
have the wall receptacle and circuit checked by a
qualified electrician to make sure the receptacle is
properly grounded and has the correct polarity.
■
Where a standard 2-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced
with a properly grounded 3-prong wall receptacle.
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD OR
ADAPTER PLUG WITH THIS APPLIANCE.
FOLLOW NATIONAL ELECTRICAL CODES AND
ORDINANCES.
A
When preparing warming drawer cabinet, make
sure the inside of the cabinet and the warming
drawer do not interfere with each other. (see
sections on preparing cabinet)
B
REMOVE PACKAGING MATERIALS: Failure to
remove packaging materials could result in damage
to the appliance. Remove all packing parts from
warming drawer including lifting up the warming
drawer to confirm all packaging is removed.
C
Remove Installation Instructions from literature
pack and read them carefully before you begin.
Be sure to place all literature, Owner’s Manual,
Installations, etc in a safe place for future
reference.
Rating plate
Recessed
receptacle 7"
max. from rear
on right side
Drill 1
1
/
2
” hole for
power cord for
left or right side
outlet location
1" = 2.5 cm; 1' = 0.3 m