“Enable HTTP/HTTPS Proxy” check box, enter the proxy server’s address and port in
the form “proxy:port” into the Proxy Settings text
box, and press the Save button.
To verify the Field Agent can successfully use the newly configured network proxy to
reach the Internet, use the Test Connection feature of the Field Agent Updater page
in the Web Console under
Technician Console, Field Agent Updater
. Internet
reachability can be tested by using either the default Update URL or any other
desired URL and pressing the Test Connection button.
If the URL is reachable, a
Test Connection Succeeded
message is displayed below the
Test Connection
button after the button is pressed. Otherwise, a message will appear
indicating that the Test Connection attempt failed.
4.3.3.3.
Configure Time Synchronization
In order for industrial data time-stamping and Field Agent diagnostic information to
operate reliably, it is important for the Field Agent to have an accurate time source.
The Field Agent has two methods of synchronizing time
–
either by using a Network
Time Protocol (NTP) server or by pulling time from a web page hosted by an HTTPS
web server with its own reliable time source. Either method can be configured in the
Web Console under
Technician Console, Time Sync Configuration
.