Permeate from each membrane housing is collected in a common manifold. The
permeate then flows through a flow meter and to the outlet point of the machine.
The concentrate leaves the last membrane housing and flows to the flow control
center (recycle/concentrate manifold). At this point, the recycle valve channels a
predetermined amount of concentrate into the pump inlet. Recycle increases
recovery while maintaining adequate cross-flow through the membranes. The other
two ports of the flow control center lead to the concentrate valve and final pressure
gauge. The concentrate valve has three functions: It controls the amount of
concentrate flowing to the drain; it controls the pressure within the machine; and it
helps control the system recovery. An autoflush solenoid is added to the flow control
center with an additional tee. The concentrate then flows through a flow meter and
to the outlet point of the machine.
1.3. Machine
Nomenclature
E-Series water purification machines are numbered in such a way as to indicate the
permeate flow you can expect from the machine and other specifications.
Example: RO,E4H-21K-DLX, 460, 6, 50-75
•
RO
indicates the machine is a reverse osmosis machine.
•
E4H
indicates the machine series (E) and 4-inch housings/membrane elements
•
H
indicates horizontal membrane element housing configuration
•
21K
indicates the rated permeate flow in thousands of gallons per day at 77
°
F
(25
°
C), i.e. 21K = 21,000 gallons per day
•
DLX
indicates the deluxe model and ECN indicates the economy model
•
460
indicates 460 VAC, 3-phase voltage to starter. Standard models offer 460 VAC,
60 Hz, 3-phase and 380 VAC, 50 Hz, 3-phase.
•
6
indicates 60 Hz operation, (50 Hz operation is also available and is indicated by a
5
in place of the
6
.
•
50-75
indicates a recovery range of 50 to 75%.
1.4. Economy (ECN) Model and Deluxe (DLX) Model Options
1.4.1. ECN
Model
E-Series ECN model water purification machines have all the features necessary for
safe, continuous production of high purity water. This assumes good quality feed
water, adequate pretreatment and regular operator maintenance, each shift or daily,
to the operation of the system.
•
50% to 75% recovery
•
Multi-stage centrifugal pump, SS construction (stainless steel castings with Noryl*
stages)
•
Base model electrical package includes NEMA-1 enclosure with a 110 VAC, 60 Hz or
220 VAC, 50 Hz single-phase control circuit; applies to all ECN models
Содержание Osmonics E4H Series
Страница 36: ......
Страница 39: ...E4H Series Operation Maintenance Manual 39 1 2450 Front Panel with Display ...
Страница 45: ...E4H Series Operation Maintenance Manual 45 A 6 Technician Level Menus ...
Страница 46: ...E4H Series Operation Maintenance Manual 46 A 1 8 Operation ...
Страница 47: ...E4H Series Operation Maintenance Manual 47 ...
Страница 48: ...E4H Series Operation Maintenance Manual 48 ...
Страница 49: ...E4H Series Operation Maintenance Manual 49 A 1 9 Relays ...
Страница 50: ...E4H Series Operation Maintenance Manual 50 A 1 10 Alarms ...
Страница 51: ...E4H Series Operation Maintenance Manual 51 A 1 11 Flow Meters ...
Страница 52: ...E4H Series Operation Maintenance Manual 52 A 1 12 4 20 mA Output ...
Страница 53: ...E4H Series Operation Maintenance Manual 53 A 1 13 System Setup ...
Страница 54: ...E4H Series Operation Maintenance Manual 54 ...
Страница 55: ...E4H Series Operation Maintenance Manual 55 ...
Страница 56: ...E4H Series Operation Maintenance Manual 56 ...
Страница 57: ...E4H Series Operation Maintenance Manual 57 A 1 14 Clock ...
Страница 58: ...E4H Series Operation Maintenance Manual 58 A 7 Security Level Menus ...
Страница 59: ...E4H Series Operation Maintenance Manual 59 A 8 Operator View Level Menus ...