9–14
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
PORT MIRRORING AND SETUP
CHAPTER 9: PORT MIRRORING AND SETUP
•
Auto-Neg
sets auto negotiation for 100 Mbps and Gigabit copper ports. There is no
no auto negotiation for fiber ports as their speeds are fixed.
• The
Port Speed
sets the speed to be 10 or 100 Mbps. This settings works only with
10/100 ports; it is ignored for 10 Mbps ports.
• The
Duplex
setting selects full duplex or half duplex capabilities for 10/100 Mbps
ports.
• The
Back Pressure
displays the state of the back pressure setting on the port. This
value can be edited in this window.
• The
Flow Control
displays the state of the flow control setting on the port. This
value can be edited in this window.
•
Priority
displays the priority set for the port. This value cannot be edited in this
window.
• The
VLAN ID
displays the VLAN set for the port. This value cannot be edited in this
window.
• The
STP State
displays the STP settings for the port. This value cannot be edited in
this window.
• The
Tagged State
displays the Tag settings on the port. This value cannot be
edited in this window.
• The
GVRP State
displays the GVRP settings on the port. This value cannot be edited
in this window.
• The
LLA
indicates the state of the Link Loss Alert feature.
The “Auto” (default) value for the
Port Speed
senses the speed and negotiates with the port
at the other end of the link for data transfer operation (half-duplex or full-duplex). The
“Auto” value uses the IEEE 802.3u auto negotiation standard for 100Base-T networks. If the
other device does not comply with the 802.3u standard, then the port configuration on the
switch must be manually set to match the port configuration on the other device.
Possible port setting combinations for copper ports are:
• 10HDx: 10 Mbps, half-duplex
• 10FDx: 10 Mbps, full-duplex
• 100HDx: 100 Mbps, half-duplex
• 100FDx: 100 Mbps, full-duplex
Possible port settings for 100FX (fiber) ports are:
• 100FDx (default): 100 Mbps, full-duplex
• 100HDx: 100 Mbps, half-duplex
Possible port settings for 10FL (fiber) ports are:
• 10HDx (default): 10 Mbps, half-duplex
• 10FDx: 10 Mbps, full-duplex
Possible port settings for Gigabit fiber-optic ports (Gigabit-SX and Gigabit-LX) are:
• 1000FDx (default): 1000 Mbps (1 GBPS), full duplex only
• Auto: The port operates at 1000FDx and auto-negotiates flow control with the
device connected to the port
To change the port speed on a transceiver port, the switch must be rebooted
Содержание MULTILINK ML2400
Страница 36: ...1 28 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL INTRODUCTION CHAPTER 1 INTRODUCTION ...
Страница 60: ...3 12 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL INSTALLATION CHAPTER 3 INSTALLATION ...
Страница 68: ...4 8 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL OPERATION CHAPTER 4 OPERATION ...
Страница 246: ...15 12 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL IGMP CHAPTER 15 IGMP ...
Страница 326: ...19 6 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL APPENDIX CHAPTER 19 APPENDIX ...