1–6
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
INTRODUCTION
CHAPTER 1: INTRODUCTION
1.3.4
Physical Specifications
MOUNTING
Vertical: ...............................................................suitable for stand-alone or rack mounting
PACKAGING
Enclosure: ..........................................................rugged high-strength sheet metal
Dimensions:.......................................................1.70 in.
×
17.0 in.
×
9.2 in. (H
×
W
×
D)
4.32 cm
×
43.2 cm
×
22.9 cm (H
×
W
×
D)
1.3.5
Approvals and Warranty
APPROVALS
FCC:.......................................................................Emissions meet FCC part 15 class A
NEBS:....................................................................level 3
ETSI:.......................................................................certified for carrier central offices
IEEE: ......................................................................IEEE P1613 environmental standard for electric power
substations
A-rated control power inputs IEEE 1613:2003
Test operation @85% to110% or rated - as per
5.1 and 5.3
AC voltage ranges
IEC60870-2-1
+ / - 10% (AC1)
DC voltage ranges
IEC60870-2-1
+ / - 15% (DC2)
ENVIRONMENTAL TESTS
Relative Humidity Cyclic
EN/IEC 60068-2-30:2005
6-day 93% @ 55deg C
(Variant 2)
Cold Temperature
EN/IEC 60068-2-1: 1993/1990
16 hours -40 deg start up (Ad)
Dry Heat Temperature
EN/IEC 60068-2-2:1994,1974
16 hours at rated upper limit, hot start up (Bd)
Humidity: -34 to 74C, 10-95% NEMA TS2
Humidity: -34 to 74C, 10-95%
Defined in 2.1.5
MECHANICAL TESTS
Sinusoidal Vibration
EN/IEC 60255-21-1 :1996,1988,
10-150hz Response/Endurance @1G (Class 1)
Shock; 2. Bump;
EN/IEC 60255-21-2:1996,1988
Class 2 for shock(30g) and Bump (20g) (Class 2)
Shock
NEMA TS2
10g, x,,y,z (As per 2.2.9)
Vibration Endurance
NEMA TS2
Vibration 5-30Hz 0.015" r 1hr(0.5g) dwell
on resonant freq
(As per 2.2.8)
Vibration
MIL-STD -167-1 (variable amplitudes 4-
50Hz)
5-30Hz,0.5g plus resonance frequency dwell
(Type 1 Environmental vibration)
FUNCTIONAL TESTS
Operating Voltage
NEMA TS2 -89-135VAC
Test @max nominal rating (As per 2.1.2)
Operational frequency
NEMA TS2 -57-63Hz
60Hz +/- 3Hz (As per 2.1.3)
SAFETY TESTS
IT -Safety
EN60950-1:2006
UL IT -Safety
UL60950-1
cUL IT -Safety
C22.2 No. 60950-1
Dielectric
IEEE 1613:2003
2000V (2000VAC & 500VAC)
Impulse IEEE
1613:2003
5000V
Standard Name
Standard Number:Date code
Severity levels Tested
Содержание MULTILINK ML2400
Страница 36: ...1 28 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL INTRODUCTION CHAPTER 1 INTRODUCTION ...
Страница 60: ...3 12 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL INSTALLATION CHAPTER 3 INSTALLATION ...
Страница 68: ...4 8 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL OPERATION CHAPTER 4 OPERATION ...
Страница 246: ...15 12 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL IGMP CHAPTER 15 IGMP ...
Страница 326: ...19 6 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH INSTRUCTION MANUAL APPENDIX CHAPTER 19 APPENDIX ...