CHAPTER 5: IP ADDRESSING
IP ADDRESSING
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
5–11
To set the SNTP server to be 3.94.210.5 (with a time out of 3 seconds and a number of
retries set to 3 times); allowing the synchronization to be ever 5 hours, the following
sequence of commands are used
ML1200#
sntp
ML1200(sntp)##
setsntp server=3.94.210.5 timeout=3 retry=3
SNTP server is added to SNTP server
database
ML1200(sntp)##
sync hour=5
ML1200(sntp)##
sntp enable
SNTP is already enabled.
ML1200(sntp)##
exit
ML1200(sntp)#
SNTP parameters can be configured through the EnerVista Secure Web Management
software with the
Configuration > SNTP
menu item. The SNTP menu allows the time zone
(hours from GMT) to be defined along with other appropriate parameters on setting the
time and synchronizing clocks on network devices.
The
edit
button allows editing of the SNTP parameters as shown below. Adding or deleting
SNTP servers is accomplished by using the add and delete buttons. Clicking the edit button
allows the specific SNTP parameter settings to be modified.
Содержание MultiLink ML1200
Страница 36: ...1 28 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL INTRODUCTION CHAPTER 1 INTRODUCTION ...
Страница 72: ...4 14 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL OPERATION CHAPTER 4 OPERATION ...
Страница 124: ...6 18 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS CONSIDERATIONS CHAPTER 6 ACCESS CONSIDERATIONS ...
Страница 146: ...8 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS USING TACACS CHAPTER 8 ACCESS USING TACACS ...
Страница 328: ...18 38 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL MODBUS PROTOCOL CHAPTER 18 MODBUS PROTOCOL ...
Страница 338: ...B 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL DC POWER INPUT CHAPTER B DC POWER INPUT ...