5–8
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
IP ADDRESSING
CHAPTER 5: IP ADDRESSING
5.3
Setting Parameters
5.3.1
Setting Serial Port Parameters
To be compliant with IT or other policies the console parameters can be changed from the
CLI interface. This is best done by setting the IP address and then telnet over to the switch.
Once connected using telnet, the serial parameters can be changed. If you are using the
serial port, remember to set the VT-100 emulation software properties to match the new
settings.
The serial port parameters are modified using the
set serial
command with the
following syntax:
set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>]
[stop=<1|1.5|2>] [flowctrl=<none|xonxoff>]
Where
<rate>
= standard supported baud rates.
Note
Changing these parameters through the serial port will cause loss of connectivity. The
terminal software parameters (e.g. HyperTerminal) will also have to be changed to match
the new settings.
To see the current settings of the serial port, use the
show serial
command to query the
serial port settings as illustrated below.
ML1200#
show serial
Baud Rate: 38400
Data: 8
Parity: No Parity
Stop: 1
Flow Control: None
5.3.2
System Parameters
The system parameters can be queried and changed. To query the system parameters,
two commands are frequently used:
show sysconfig
and
show setup
. Usage for both
commands is illustrated below.
The following example lists system parameters using the
show setup
command. Most
parameters here cannot be changed.
ML1200#
show setup
Version: ML1200 build 3.3.0 March 19 2009 14:22:43
MAC Address: 00:20:06:27:0a:e0
IP Address: 3.94.247.41
Subnet Mask: 255.255.252.0
Gateway Address: 3.94.244.1
CLI Mode: Manager
System Name: ML1200
System Description: 12 Port Modular Ethernet Switch
System Contact: [email protected]
System Location: Markham, Ontario
System ObjectId: 1.3.6.1.4.1.13248.12.7
ML1200#
The following example lists system parameters using the
show sysconfig
command.
Most parameters here can be changed.
Содержание MultiLink ML1200
Страница 36: ...1 28 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL INTRODUCTION CHAPTER 1 INTRODUCTION ...
Страница 72: ...4 14 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL OPERATION CHAPTER 4 OPERATION ...
Страница 124: ...6 18 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS CONSIDERATIONS CHAPTER 6 ACCESS CONSIDERATIONS ...
Страница 146: ...8 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS USING TACACS CHAPTER 8 ACCESS USING TACACS ...
Страница 328: ...18 38 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL MODBUS PROTOCOL CHAPTER 18 MODBUS PROTOCOL ...
Страница 338: ...B 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL DC POWER INPUT CHAPTER B DC POWER INPUT ...