CHAPTER 1: INTRODUCTION
INTRODUCTION
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
1–3
1.3
Specifications
PERFORMANCE
Filtering / Forwarding Rate:............................................................... Ethernet(10Mb):14,880 pps
Fast Ethernet(100Mb): 148,800 pps
Gigabit Ethernet (1000Mb): 1, 488,000
pps
Switching Processing Type: ............................................................... Store and Forward with IEEE 802.3x
full-duplex flow -control, non-blocking
Data Rate: ................................................................................................. 10Mbps,100Mbps and 1000Mbps
Address Table Capacity: ..................................................................... 4K node, self-learning with address
aging
Packet buffer size : ............................................................................... 240KB for 10/100 and 120KB for
1000Mb
Latency: ..................................................................................................... 5
μ
s + packet time (100 to 100Mbps)
15
μ
s + packet time (10 to 10 Mbps,
and 10 to 100Mbps)
Throughput with 12 10/100 and 2Glink max:........................... 4.76M pps (Transmit)
Back plane:................................................................................................ 2.66Gb/s per slot
NETWORK STANDARDS AND COMPLIANCE, HARDWARE
Ethernet V1.0/V2.0 IEEE 802.3: ........................................................ 10BASE-T,
IEEE 802.3u: .............................................................................................. 100Base-TX, 100BASE-FX
IEEE 802.3z: .............................................................................................. 1000BASE-X Ethernet (Auto-
negotiation)
IEEE 802.3ab: ........................................................................................... 1000BASE-X Ethernet
IEEE 802.1p: .............................................................................................. Priority protocol
IEEE 802.1d: .............................................................................................. Spanning tree protocol
IEEE 802.1w: ............................................................................................. Rapid Spanning tree protocol
IEEE 802.1q: .............................................................................................. VLAN Tagging
IEEE 802.3x: ............................................................................................... Flow Control
IEEE 802.3ad: ........................................................................................... Link Aggregation (Trunking)
IEEE 802.1x: .............................................................................................. Port based Network access control
IEEE 802.3af: ............................................................................................ Power over Ethernet
MAXIMUM 10 MBPS ETHERNET SEGMENT LENGTHS
Unshielded twisted pair ...................................................................... 100 m (328 ft)
Shielded twisted pair:........................................................................... 150 m (492 ft)
10BASE-FL multi-mode fiber optic:................................................ 2 km (6,562 ft)
10BASE-FL single-mode fiber optic:.............................................. 10 km (32,810 ft)
MAXIMUM STANDARD FAST ETHERNET SEGMENT LENGTHS:
10BASE-T (CAT 3, 4, 5 UTP): ................................................................ 100 m (328 ft)
100BASE-TX (CAT 5 UTP):..................................................................... 100 m (328 ft)
Shielded twisted pair:........................................................................... 150 m (492 ft)
100BASE-FX, half-duplex, multi-mode:........................................ 412 m (1350 ft)
100BASE-FX, full-duplex, multi-mode:.......................................... 2.0 km (6,562 ft)
100BASE-FX, half-duplex, single-mode: ...................................... 412 m (1350 ft)
100BASE-FX, full-duplex, single-mode:....................................... 20.0 km (66K ft)
100BASE-FX, full-duplex, Long Reach: ......................................... 40.0 km (132K ft)
MAXIMUM STANDARD GIGABIT ETHERNET SEGMENT LENGTHS:
1000BASE-T (CAT5e or higher is recommended):.................... 100 m (328 ft)
1000BASE-SX, full-duplex, multi-mode(62.5
μ
m cable):........ 220m
Содержание MultiLink ML1200
Страница 36: ...1 28 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL INTRODUCTION CHAPTER 1 INTRODUCTION ...
Страница 72: ...4 14 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL OPERATION CHAPTER 4 OPERATION ...
Страница 124: ...6 18 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS CONSIDERATIONS CHAPTER 6 ACCESS CONSIDERATIONS ...
Страница 146: ...8 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL ACCESS USING TACACS CHAPTER 8 ACCESS USING TACACS ...
Страница 328: ...18 38 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL MODBUS PROTOCOL CHAPTER 18 MODBUS PROTOCOL ...
Страница 338: ...B 8 MULTILINK ML1200 MANAGED FIELD SWITCH INSTRUCTION MANUAL DC POWER INPUT CHAPTER B DC POWER INPUT ...