GE Multilin
G60 Generator Protection System
B-49
APPENDIX B
B.4 MEMORY MAPPING
B
87CB
Remote RTD 12 Value
0 to 200
°C
1
F002
0
FlexState Settings (Read/Write Setting)
8800
FlexState Parameters (256 items)
0 to 4294967295
---
1
F300
0
Digital Elements (Read/Write Setting) (48 modules)
8A00
Digital Element 1 Function
0 to 1
---
1
F102
0 (Disabled)
8A01
Digital Element 1 Name
---
---
---
F203
“Dig Element 1“
8A09
Digital Element 1 Input
0 to 4294967295
---
1
F300
0
8A0B
Digital Element 1 Pickup Delay
0 to 999999.999
s
0.001
F003
0
8A0D
Digital Element 1 Reset Delay
0 to 999999.999
s
0.001
F003
0
8A0F
Digital Element 1 Block
0 to 4294967295
---
1
F300
0
8A11
Digital Element 1 Target
0 to 2
---
1
F109
0 (Self-reset)
8A12
Digital Element 1 Events
0 to 1
---
1
F102
0 (Disabled)
8A13
Digital Element 1 Pickup LED
0 to 1
---
1
F102
1 (Enabled)
8A14
Reserved (2 items)
---
---
---
F001
0
8A16
...Repeated for Digital Element 2
8A2C
...Repeated for Digital Element 3
8A42
...Repeated for Digital Element 4
8A58
...Repeated for Digital Element 5
8A6E
...Repeated for Digital Element 6
8A84
...Repeated for Digital Element 7
8A9A
...Repeated for Digital Element 8
8AB0
...Repeated for Digital Element 9
8AC6
...Repeated for Digital Element 10
8ADC
...Repeated for Digital Element 11
8AF2
...Repeated for Digital Element 12
8B08
...Repeated for Digital Element 13
8B1E
...Repeated for Digital Element 14
8B34
...Repeated for Digital Element 15
8B4A
...Repeated for Digital Element 16
8B60
...Repeated for Digital Element 17
8B76
...Repeated for Digital Element 18
8B8C
...Repeated for Digital Element 19
8BA2
...Repeated for Digital Element 20
8BB8
...Repeated for Digital Element 21
8BCE
...Repeated for Digital Element 22
8BE4
...Repeated for Digital Element 23
8BFA
...Repeated for Digital Element 24
8C10
...Repeated for Digital Element 25
8C26
...Repeated for Digital Element 26
8C3C
...Repeated for Digital Element 27
8C52
...Repeated for Digital Element 28
8C68
...Repeated for Digital Element 29
8C7E
...Repeated for Digital Element 30
8C94
...Repeated for Digital Element 31
8CAA
...Repeated for Digital Element 32
8CC0
...Repeated for Digital Element 33
8CD6
...Repeated for Digital Element 34
8CEC
...Repeated for Digital Element 35
8D02
...Repeated for Digital Element 36
8D18
...Repeated for Digital Element 37
8D2E
...Repeated for Digital Element 38
8D44
...Repeated for Digital Element 39
8D5A
...Repeated for Digital Element 40
8D70
...Repeated for Digital Element 41
Table B–10: MODBUS MEMORY MAP (Sheet 41 of 68)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание Multilin g60
Страница 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Страница 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 130: ...3 68 G60 Generator Protection System GE Multilin 3 4 FIELD AND STATOR GROUND MODULES 3 HARDWARE 3 ...
Страница 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 538: ...8 6 G60 Generator Protection System GE Multilin 8 1 PHASE DISTANCE THROUGH POWER TRANSFORMERS 8 THEORY OF OPERATION 8 ...
Страница 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...