6
ELECTRICAL REQUIREMENTS
L5-30R Receptacle
L5-30P Plug
Corner Installation
Install the receptacle
on the left rear
corner of the
wine vault.
Corner Installation
Install the receptacle
on the left side wall
near the front.
Alcove Installation
Install the receptacle
outside the alcove
where it will be
accessible.
Flat Wall
Installation
Install the receptacle
adjacent to the left
rear corner of the
wine vault.
Free-Standing
Installation
Install a recessed
receptacle in the
ceiling directly
above the power
cord location.
LOW CEILING
Ceiling height is under 8 ft. (7’10” min.). The
receptacle must be installed in an accessible location, approx. 7’8”
above the floor, OUTSIDE the vault installation location (footprint).
Corner Installation
Install the receptacle
on the left side wall
near the back.
Corner Installation
Install the receptacle
on the left side wall
near the front.
Alcove Installation
Install the receptacle
outside the alcove
where it will be
accessible.
Flat Wall
Installation
Install the receptacle
adjacent to the left
side wall near the
back.
Free-Standing
Installation
Install a receptacle
in the ceiling where
it will be accessible
and inconspicuous.
KEY:
= Approx. power cord location
= Approx. receptacle location
HIGH CEILING
Ceiling height is 8 ft. or over. The receptacle must be
installed in an accessible location, approx. 7’10” above the floor,
outside or inside the vault installation location (footprint).
KEY:
= Approx. power cord location
= Approx. receptacle location
■
■
A 120V, 60 Hz, 30-amp dedicated power supply is required.
A dedicated 30-amp branch circuit must be properly grounded
and protected by a time-delay fuse.
■
■
Wiring for the cooling unit, lights and touch screen computer is
routed through a single power source with a NEMA L5-30P twist-lock
plug that must mate with the NEMA L5-30R electrical receptacle.
■
■
The power cord will exit at the top of the vault. Plan to install the
electrical outlet within the guidelines shown below. It should be in an
inconspicuous location towards the left side. In a built-in situation,
the connection may be hard-wired, using conduit, by a qualified
electrician. All installations must be according to local codes.
■
■
The electrical system in the wine vault is protected by a surge
protector to prevent damage caused by power surges and spikes.
It is important to locate the electrical receptacle where it will be accessible. The exact
location of the receptacle must be planned depending on the installation situation.