Ductwork

Component Cooktop System

10

Venting
Options

Through Floor Between Joists

Through Floor & Under Joists

Multiple cooktops and downdraft vent units
may be used in a single arrangement.
• Plan the route for venting exhaust to the

outdoors.

• Ductwork must be vented to outdoors - never

to a crawl space, attic or other enclosed space.

• Duct should be located between floor joists or

wall studs whenever possible.

• Blower and motor assembly can be installed

on an outside wall. JXBC55 optional outdoor
cover accessory is required and must be
ordered with each downdraft venting unit.

• Every downdraft vent and downdraft grill

must have it’s own, separate duct run.

Ductwork
Advance
Planning

• Use the shortest and straightest duct run

possible.
– Duct run for Downdraft Grill Component,

ZEW166, should not exceed equivalent
length of 100 feet.

– Duct run for Downdraft Vent, ZEW176,

should not exceed equivalent length of
150 feet.

– Refer to “Duct Fittings” chart to calculate

equivalent length for various duct
configurations.

• The downdraft blower system is designed for

use with 3-1/4" x 10" ductwork. It can be
transitioned to 6" round.

• Ductwork MUST be vented to the outside –

never into a crawl space, attic or other
enclosed space.

Inside Wall 

To Roof

Direct To Outdoors 

With JXBC55 Mounted

On Outside Wall

Optional
Ductwork
Arrangement

6" PVC duct should be used when installing
under a concrete slab.
• Use recommended wall caps with damper.

Do not use laundry type wall caps.

• Ductwork must be vented to the outside.
• Each cooktop blower system requires a

separate duct system.

NOTE: 

Local building code must be followed for installation and in

specifying approved type and schedule of PVC duct used.

Содержание Monogram ZEW145

Страница 1: ...GE Monogram Installation Instructions Component Cooktop System Models ZEW145 ZGW124 ZGW125 ZEW155 ZEW166 ZEW176 www monogram com ...

Страница 2: ...nical skills Proper installation is the responsibility of the installer other naturally vented systems To minimize the chance of interference with such naturally vented systems follow the heating equipment manufacturer s guidelines and local codes Also follow the guidelines in ASHRAE Standard 62 1989 Ventilation for Acceptable Indoor Air Quality section 5 8 When following these guidelines be sure ...

Страница 3: ...oduct Dimensions ZEW145 Radiant Cooktop Component 240 and 208 volt dual rated Parts supplied 44 flexible conduit One joiner strip Two sets clamping screws One chassis support brace 3 1 4 15 1 2 21 Allow additional 1 depth for clearance of flexible conduit ZEW155 Updraft Grill Cooktop Component 240 volt Parts supplied Grease collection jar 48 flexible conduit One joiner strip Two sets clamping scre...

Страница 4: ...and controls ZGW125 Gas Cooktop Component with left hand controls Parts supplied with each 1 2 inlet pipe Pressure regulator One joiner strip Two sets clamping screws One chassis support brace NOTE Gas components are designed for natural gas operations and cannot be converted to LP operation If installation includes a drawer beneath gas cooktop make allowance for gas inlet pipe Gas inlet extends 1...

Страница 5: ...comply with the National Fuel Gas Code ANSI Z223 1 latest edition UL A G A approved Installation Options Multiple gas and electric components can be combined to form one custom cooking arrangement Multiple electric components can operate from a single junction box if local codes permit Multiple gas components can operate from a manifold as permitted by local codes Updraft components can be vented ...

Страница 6: ...um clearance between the countertop and the cabinet bottom EXCEPTION Installation of a listed microwave oven or cooking appliance over the cooktop s shall conform to the installation instructions packed with that appliance Installation must conform with local codes Clearances When installed electric components require the following clearances 2 min from front of cooktop to front edge of countertop...

Страница 7: ...de Orientation Minimum clearance is 4 between cooktops in separate cutouts This clearance does not apply when multiple component cooktops are installed in one cutout NOTE Do not install a downdraft vent in a side to side orientation behind a gas or radiant component This would require the user to reach over a heated surface to access the control Find Dimension A in chart below and on the following...

Страница 8: ...Grill Component 20 3 4 ZEW155 Updraft Grill Component 15 3 8 Downdraft Vent ZEW176 Component 5 1 8 Connection between two cooktops including updraft grill and non vent Joiner Strip side of downdraft grill 3 4 Connection between cooktop and Downdraft downdraft vent or vent Joiner Strip side of downdraft grill 1 4 Provide finished look to Cooktop and component cooktop Downdraft arrangement Do not Ve...

Страница 9: ...ndraft Radiant 35 1 2 Grill RH Gas Radiant Downdraft Radiant 34 5 8 Vent LH Gas RH Gas Downdraft Radiant Radiant 50 3 4 Grill RH Gas RH Gas LH Gas Radiant Downdraft Radiant Downdraft Radiant 54 3 4 Vent Vent Downdraft Radiant LH Gas Downdraft Radiant 55 1 4 Vent Vent RH Gas RH Gas Radiant Downdraft Downdraft Radiant 55 5 8 Vent Grill LH Gas RH Gas Cutout information multiple component units 9 See ...

Страница 10: ...uct run for Downdraft Grill Component ZEW166 should not exceed equivalent length of 100 feet Duct run for Downdraft Vent ZEW176 should not exceed equivalent length of 150 feet Refer to Duct Fittings chart to calculate equivalent length for various duct configurations The downdraft blower system is designed for use with 3 1 4 x 10 ductwork It can be transitioned to 6 round Ductwork MUST be vented t...

Страница 11: ...t or under the floor The blower will fit between floor joists on 16 centers For installation where the blower is mounted inside the cabinet attach the mounting supports to the bottom corners of the blower housing The motor is on the bottom side the 6 round opening is the top side If the blower is installed under the floor attach the mounting supports to the top corners the side with the 6 round op...

Страница 12: ...mum equivalent length is 150 feet Note Do not exceed maximum permissable equivalent lengths Flexible ducting If flexible metal ducting is used all the equivalent length values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible Do NOT use flexible plastic ducting Duct fittings Actual length of straight duct plus duct fitting equival...

Страница 13: ... location L H Gas Unit R H Gas Unit 12 Min 2 1 2 from Rear Edge of Cutout 4 7 16 Gas Supply Options 4 7 16 Electrical Supply The radiant component operates on 240 208 volt 60 Hz Updraft grill and downdraft grill components operate on 240 volt 60 Hz Gas and downdraft vent components operate on 120 volt 60 Hz from a separate junction box A dedicated circuit protected by a time delay fuse or circuit ...

Страница 14: ...ng three nuts with a 5 16 nutdriver Discard nuts Attach joiner strip to first cooktop by tightening flanged nuts supplied over the flanges Place the two cooktops into the countertop cutout Slide the cooktops together so that the slots in the joiner strip are engaged by the studs There should be no gaps between cooktops and joiners Press together firmly to assure a tight fit Place flanged nuts in e...

Страница 15: ...h holes and then backing out before installation This will make the joining process easier Replace endcap with downdraft joiner strip using the same three nuts If the vent is to be installed at the end of the countertop opening attach downdraft endcap to that side Place the downdraft vent and cooktop into the cutout Remove two screws from the front of cooktop chassis Drive the two screws into hole...

Страница 16: ...ach downdraft joiner strip to cooktop Place cooktop next to downdraft vent in the cutout Drive two phillips head screws into pre tapped holes Use a phillips screwdriver bit socket To install additional vent or cooktop s refer to Joining Multiple Cooktops Loosen screws on hold down brackets at each end of cooktop Extend the bracket to reach the underside of the countertop Tighten screws Drive a lon...

Страница 17: ...stic socket on the underside of the vent controls Fasten the wire box on the conduit over the plug and onto the bottom of the control box with screws provided The blower conduit is long enough to reach the vent connection when installed in the cabinet below The conduit will also reach some blower installations below the cabinet floor If the blower conduit is not long enough to reach the vent conne...

Страница 18: ...ich is white or gray 4 Conductor branch circuit Connect red lead to branch circuit red lead Connect black lead to branch circuit black lead Break connection between cooktop white lead to bare or green conductor Connect cooktop white lead to branch circuit neutral lead which is white or gray Ground unit by connecting bare conductor of cooktop to branch circuit bare or green lead ground lead The fra...

Страница 19: ... shown Check for proper ignition Push in control knob and turn 90 to HIGH position First test may require some time while air is flushed out of the gas line Turn knob to OFF Repeat the procedure for each burner Burner Grate Burner Cap Trim Ring Install downdraft vent filter Place filter into the opening and on top of the supports Place grille over the filter Control Knob Grille Removed Filter CAUT...

Страница 20: ... in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Monogram General Electric Company Louisville KY 40225 Pub No 49 8834 2 Dwg No 164D3333P076 Printed in USA N D 237 8 01 953 0559 000 Rev 1 ...

Отзывы: