GE Monogram ZDOD240 Скачать руководство пользователя страница 4

4

Design Guide

THE INSTALLATION SPACE

Free-Standing – Use canopy top Built-In – Remove canopy top 

(if needed)

Choose the location:

• This product has been designed as a free-standing unit; 

however, if desired, it may also be built-in. 

• These products may be closed in on the top and 

 

three sides as long as the front is unobstructed for  

air circulation and proper access to the door.

• 

Do not operate these products where the temperature 

will go below 45°F (7°C) or above 120°F (49°C).

• Unit must be installed on a structurally sound and 

 

level surface strong enough to support a fully loaded 

refrigerator, or approx. 250 lbs.

• The Outdoor/Indoor Refrigerator can be used

 

free-standing.

*For a standard installation:

 The product must be installed  

so that the stainless steel front will project 1-7/8" forward  
of adjacent cabinets. This position will allow a full door swing 
and prevent interference with adjacent cabinetry.  
The opening between cabinets must be 23-3/4" minimum.

**For a flush installation: Install a 1/2"-wide filler strip on 

the hinge side. The filler strip will act as a spacer between 

the door case and adjacent cabinets and will prevent 

interference with the cabinet door swing. Recess the filler 

strip 1-7/8" back from the front face of the refrigerator, or 
even with the front edge of the product case (behind the 
gasket). The width of the opening must be 24-1/2" (including 

the 1/2" filler strip).

Additional Specifications

 A 120 volt 60Hz., 15 or 20 amp power supply is 

required. An individual properly grounded branch circuit 

or circuit breaker is recommended. Install a properly 

grounded 3-prong electrical receptacle recessed into 

the back wall as shown. Electrical must be located 

on rear wall as shown. 

THIS PRODUCT MUST BE 

CONNECTED TO A POWER SOURCE WITH GROUND 

FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION 

WHEN INSTALLED IN AN OUTDOOR LOCATION. LOCAL 

CODES MAY REQUIRE A SEPARATE CIRCUIT.

THE INSTALLATION SPACE (cont.)

These products will fit flush 

to adjacent cabinets when 

installed with a 1/2" filler panel 

or cleat. The filler panel should 

be recessed or set back behind 

the door and even with the front 

edge of the product case.

In a standard installation,  

the product will project 1-7/8" 

forward of adjacent cabinets.

Flush 

Installation

CABINET

CABINET

CABINET

CABINET

1-7/8"

1/2"

120°

120°

110°

110°

Filler panel or cleat 

to be set back even 

with front of case.

Front edge of product case

Front face

Front face

Front edge of product case

Standard  

Installation

NOTE:

  

Handle and 

handle standoff 

depth is 2-7/8"

Содержание Monogram ZDOD240

Страница 1: ...Design Guide with Installation Instructions Outdoor Indoor Refrigerator ZDOD240 monogram com...

Страница 2: ...g or making repairs Repairs should be made by a qualified service technician AVERTISSEMENT Il ne faut utiliser cet appareil que pour l usage pour lequel il a t construit Il faut r parer ou remplacer i...

Страница 3: ...e fine finish we also strongly advise that you apply stainless steel cleaner monthly All stainless steel can be damaged by the following sub stances Care must be taken not to allow these substances to...

Страница 4: ...the cabinet door swing Recess the filler strip 1 7 8 back from the front face of the refrigerator or even with the front edge of the product case behind the gasket The width of the opening must be 24...

Страница 5: ...hen installing the unit in a free standing configuration the top canopy must be left in place If replacing the top canopy make sure the three latches in the front slide into the front lip of the canop...

Страница 6: ...ch mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electrician...

Страница 7: ...is installed under a countertop adjust the leveling legs until the unit is resting firmly against the bottom of the countertop If alignment with adjacent cabinetry is an issue use a shim to secure the...

Страница 8: ...be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject...

Отзывы: