Thermistor Error Displays
(OFF LED 2 or 3 Blinks
During Normal Operation)
When the
OFF
LED blinks 2 or 3 times, an error is
indicated. These errors will occur at any time during
normal operation if a thermistor fails.
2 Blinks
―
OFF
LED is blinking twice in repeating
intervals. This signi
fi
es a bin thermistor failure.
Check that the bin thermistor is plugged in to
•
the control box.
Check that the bin thermistor is not open or
•
shorted. Replace the thermistor if it is open or
shorted.
3 Blinks
―
OFF
LED is blinking three times in
repeating intervals. This signi
fi
es a harvest failure.
Check that the evaporator thermistor is
•
connected to the sealed-system tubing.
If the thermistor is plugged in, ensure that it is
•
fully connected to the control box. (The icemaker
will operate on a timed cycle if the evaporator
thermistor is unplugged.)
Check the resistance of the thermistor. If the
•
thermistor checks good, look for a hot gas
failure, a sealed system leak, or a restriction.
Models with Internal Drain Pumps (ZPK1)
The power cord on the internal drain pump is
connected to a 120 VAC wall outlet. The icemaker
is then connected to the 120 VAC outlet on the
drain pump. If the drain pump fails, or if the drain
becomes blocked, power is shut off to the 120 VAC
outlet on the drain pump.
When the unit is
fi
rst plugged in, the drain pump will
run for 20 sec. The power can be disconnected and
reconnected to verify that the pump is operating
properly.
Water from the icemaker reservoir, or melting ice
from the bin, drains down the bin drain tube into the
pump inlet, and then into the drain pump chamber.
As the water level rises, it bridges the
Full
contacts,
and the pump starts to run.
The pump discharges the water through the outlet
and the check valve. When the
Full
connection is
removed, the pump runs for an additional 12 sec. to
empty the tank.
If the water level in the drain pump continues to
rise, due to a slow or blocked drain or a blocked
vent hose, and touches the
Overfi ll
contact, power
will be turned off to the drain pump 120 VAC outlet,
causing the icemaker to turn off.
Internal Drain Pump
Green
Black
White
Overfi ll Contacts
Pump Outlet &
Check Valve
Pump Inlet
Vent Outlet
Screen Washer
Full Contacts
Contacts sense continually
through the water
Connector Hose (Contains
Screen Washer)