– 23 –
Remove the recirculation pump outlet tube.
6.
Remove 3 hex-head screws from the pump
7.
mounting bracket and remove the pump/water
level sensor assembly.
Remove the 2 thumbscrews from the reservoir
5.
and remove the reservoir from the icemaker.
Outlet Tube
Water Level Sensor
Remove the ice from the storage bin prior to
removing the recirculation pump.
To remove the water level sensor:
Remove the hex-head screw from the water
1.
recirculation pump shield and remove the shield.
(See
Water Recirculation Pump
.)
Disconnect the water level sensor electrical
2.
connection.
Remove the retaining clips, if present.
3.
Pull the sensor up and out of the bracket.
4.
Disconnect
Water Level Sensor