30
P21/P22/P23 Protected Network Station
05-4161A01, Rev. C
3. Con
fi
gure Radio A (upper unit) as appropriate. Save the con
fi
gura-
tion
fi
le to a TFTP server as described in the transceiver manual.
4. Set the front panel
RADIO SELECTION
switch to “
B
”. Download the
saved con
fi
guration
fi
le into Radio B (lower unit).
5. This completes the con
fi
guration procedure. Set the front panel
switch to
AUTO
, re-install the top cover, and the unit is ready for ser-
vice.
4.2 Initial MDS entraNET Programming and Setup
This section presents menu settings for MDS entraNET transceivers
used in P22 Protected Network Stations. Only menus pertaining directly
to protected network operation are covered here. Please refer to the
transceiver manual (Part No. 05-4055A01) for a complete list of radio
commands and other operation details.
(For instructions on programming MDS iNET/iNET-II Series trans-
ceivers, see “Initial MDS iNET/iNET-II Programming and Setup” on
Page 23.)
NOTE:
MDS entraNET radios used in a Protected Network Station
must have firmware revision 2.3.7 or higher installed. Consult
the factory for firmware availability.
Redundancy Menu
Redundancy is available only at the AP. The Redundancy Menu is used
in protected installations where a backup transceiver can be immedi-
ately placed online should a primary unit fail. This protects against
“single point of failure” scenarios. The Redundancy menu contains
selections and settings that are used to manage redundancy functions.
NOTE:
The chassis uses a Switchover Logic Board (Part No.
03-6061Axx). This board is similar in appearance to the one
used in P20 configurations, but they are not interchangeable.
Consult factory for assistance with replacement PCBs.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com