29
P21/P22/P23 Protected Network Station
05-4161A01, Rev. C
Invisible place holder
Figure 25. Redundancy Configuration Options
The Redundancy Configuration Options screen (Figure 25) allows you
to set the threshold limits or behavior for many redundancy-triggering
events. To configure an option, simply select the letter of the menu item
and follow the instructions at the bottom of the screen.
“Mirrored Configuration” of Transceivers
To ensure proper operation after a switchover, it is important that both
transceivers in a Protected Network Station have the identical configu-
ration profile. This can be accomplished using a configuration file as
follows:
1. Install transceivers in the chassis as described earlier. Apply power
to the Protected Network Station.
2. Set the front panel
RADIO SELECTION
switch to “
A
”.
RF Power Control Saturated Low
There is a hardware defect that is causing the
Power Control Loop to fail.
Initialization Error
The software failed to initialize properly.
Additional Menu Item for Remotes:
SNR Below Threshold
The Signal to Noise ratio is below the
user-defined threshold.
For proper detection, the following value must
be configured in the Redundancy
Configuration Options menu on the Remote:
SNR Threshold x
Additional Menu Item for Remotes:
RSSI Below Threshold
The Receiver Signal Strength Indication is
below the user-defined threshold.
For proper detection, the following value must
be configured in the Redundancy
Configuration Options menu on the Remote:
RSSI Threshold x (dBm)
RSPSupply - 1-888-532-2706 - www.RSPSupply.com