Line Mode
- Selection of the operation line mode of the serial port. Choices are:
-
RS232 (DEFAULT)
-
RS485 - 2 Wire
-
RS485 - 4 Wire
Baud Rate
- The serial port baud rate in bps. Choices 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200 (DEFAULT), 230400.
Byte Format
- The data byte format in bits, parity and stop bits: Choices are:
-
7N1 - 7 char bits, no parity, 1 stop bit
-
7E1 - 7 char bits, even parity, 1 stop bit
-
7O1 - 7 char bits, odd parity, 1 stop bit
-
7N2 - 7 char bits, no parity, 2 stop bits
-
7E2 - 7 char bits, even parity, 2 stop bits
-
7O2 - 7 char bits, odd parity, 2 stop bits
-
8N1 - 8 char bits, no parity, 1 stop bit (DEFAULT)
-
8E1 - 8 char bits, even parity, 1 stop bit
-
8O1 - 8 char bits, odd parity, 1 stop bit
-
8N2 - 8 char bits, no parity, 2 stop bits
-
8E2 - 8 char bits, even parity, 2 stop bits
-
8O2 - 8 char bits, odd parity, 2 stop bits
Hw Flow Control
- Hardware flow control enable/disable (DEFAULT) using RTS/CTS lines
Vmin
- Receive Buffer Size - The minimum number of data bytes that will be buffered by the serial
port before handling of the data to be processed by the terminal server. (255 = DEFAULT).
Vtime
- Receive Inter-Byte Timeout - The amount of time between bytes of data on the serial port (
in
multiples of 1 millisecond
), that indicate the end of a serial message ready to be processed by the
terminal server. (100 = DEFAULT)
From the CLI, this sequence shows how to add console access to the COM1 and COM2 serial ports and
set the COM2 baud rate to 19200 bps:
% set services serial console serial-ports [
COM1 COM2
]
% set services serial ports
COM2
baud-rate
b19200
% commit
Terminal Server Settings
When configuring a serial port that will be used as a terminal server the VMIN and VTIME settings need
additional explanation. As described above VMIN is a number describing bytes that are received from the
interface, while VTIME is in 100
th
s of a second (100 milliseconds) intervals. They act together to control
serial data collection and transmission as described below:
VMIN == 0; VTIME == 0: The terminal server will continuously read to see if a byte if data is
available and process each byte.
NOTE
While this is a valid mode in most cases this causes a high processing load on the device that
may impact performance of other operations of the device.
VMIN > 0; VTIME == 0: The terminal server waits to process data until at least VMIN bytes
of serial data are received.
Содержание MDS ORBIT ECR
Страница 15: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 15 ...
Страница 35: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 35 ...
Страница 145: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 145 ...
Страница 188: ...188 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 302: ...302 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F Figure 3 224 SNMP Main Page ...
Страница 380: ...380 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 389: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 389 ...
Страница 393: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 393 ...
Страница 407: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 407 ...
Страница 449: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 449 ...
Страница 451: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 451 ...
Страница 452: ...452 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 453: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 453 ...
Страница 459: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 459 NOTES ...
Страница 460: ...460 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 461: ......
Страница 463: ...GE MDS LLC Rochester NY 14620 Telephone 1 585 242 9600 FAX 1 585 242 9620 www gemds com 175 Science Parkway ...