The unit is designed to store up to 10100 events before rolling over losing event history. An alarm
(
eventlog_high_water
) is generated when approaching the maximum event storage limit. Another alarm
(
eventlog_full
) is generated when the maximum value is reached. Each time the log reaches the maximum
the value 100 oldest events will be deleted.
By default for security the logging is configured to be verbose and the log file may fill in a relatively short
time for a very active system.
All events can be configured to be logged to any combination of the following locations based on the
event type:
Local
: Store event in the local event log.
Netconf-notification
: generate a NETCONF notification
Syslog
: Forward events to a remote syslog server.
There are a number of default rules which can be modified to be active on the web UI. Refer to the
Default Event Rule
table located on the page
Logging---> Basic Config.
Each rule has the following setting types:
Name
- system recognized short name
Description
- Supplied descriptive text
Local
- If true, this event is stored in the local event log. True/False
Priority
- If logging to Syslog
-
alert - action must be taken immediately
-
crit - critical condition
-
debug - debug-level messages
-
emerg - system is unusable
-
err - error condition
-
info - informational set
-
notice - normal but significant condition
-
warning - warning condition
Syslog Facility
- If logging to SysLog selection of : auth, authpriv, cron, daemon, ftp, kern,
lpr, mail, news, syslog, user, uucp, local0, local1, local2, local3, local4, local5, local6, local7
Syslog
- If true, forward events of this type to a syslog server.
SNMP Notification
- If true, generate an SNMP notification (trap or inform) for events of this
type.
SNMP Notify Name
- Selection of a set of management targets which should receive
notifications, as well as the type of notification (trap/inform). These should be sent to each
selected management target. If the notify-name is not configured, the notification is sent to all
configured targets
NETCONF Notification
- If true, generate a NETCONF notification for events of this type.
Alarm
- If true, generate an alarm output for events of this type.
Alarm Outputs
- Generate an alarm on all of these alarm outputs.
Logs are stored in the Event Log, which may be viewed on the Web UI by navigating to
Logging --->
Status
and scrolling down to
Event Log
section, as shown in the following example.
Содержание MDS ORBIT ECR
Страница 15: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 15 ...
Страница 35: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 35 ...
Страница 145: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 145 ...
Страница 188: ...188 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 302: ...302 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F Figure 3 224 SNMP Main Page ...
Страница 380: ...380 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 389: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 389 ...
Страница 393: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 393 ...
Страница 407: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 407 ...
Страница 449: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 449 ...
Страница 451: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 451 ...
Страница 452: ...452 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 453: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 453 ...
Страница 459: ...MDS 05 6632A01 Rev F MDS Orbit MCR ECR Technical Manual 459 NOTES ...
Страница 460: ...460 MDS Orbit MCR ECR Technical Manual MDS 05 6632A01 Rev F ...
Страница 461: ......
Страница 463: ...GE MDS LLC Rochester NY 14620 Telephone 1 585 242 9600 FAX 1 585 242 9620 www gemds com 175 Science Parkway ...