GE JV536 Скачать руководство пользователя страница 12

Ties

12

REMOVE DUCT KNOCKOUT(S)

If 

recirculating

, non-vented ductless (optional for 

JV5 Series models only), see note below and 

skip to 

Step 12 D and proceed

We do not recommend the

recirculated configuration for JV6 Series models.

Using a flat blade screwdriver, remove the appropriate

duct knockout(s)

from the top or back of the hood.

3

1

4

x 10

Rectangular

vertical discharge.

Remove top rectangular
duct knockout only.

7

Round vertical

discharge. 

Remove semi-

circular duct knockout and top
rectangular duct knockout.

3

1

4

x 10

Rectangular

horizontal discharge. 

Remove

rear rectangular duct knockout only.

FOR HORIZONTAL DISCHARGE
INSTALLATIONS ONLY:

Remove the 

plate

(on models so equipped) in front 

of the horizontal discharge knockout. Cut the 

ties

lift plate out and discard plate. DO NOT REMOVE 
the 

metal strip

held in place with two 

screws

.

Metal strip

Plate

FOR 3

1

4

X 10

RECTANGULAR

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Attach 

exhaust adaptor/damper

over knockout

opening with two exhaust adaptor screws. Make sure
damper 

pivot

is nearest to 

top/back edge

of hood.

Remove 

tape

from damper flap.

Up to 1

side-to-

side adjustment

Tape

Top/back edge

Exhaust adaptor/damper
(vertical discharge position
shown)

Pivot

FOR 7

ROUND VERTICAL

DUCTED DISCHARGE
INSTALLATIONS ONLY:

Re-install the 

7

round exhaust adaptor

with its

screws, removed in Step 2 under the “Prepare the
Hood” section.

8

9

10

11

7

round

exhaust
adaptor

NOTE: 

The 7

round exhaust adaptor can be installed 

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need 
to be trimmed to clear the electrical cable clamp.

NOTE: 

The 7

round damper is not included with 

this product. It can be purchased as a kit by calling
800.626.2002. Order kit number JXDA23.

Installation Instructions

Screw

NOTE: 

The exhaust adaptor/damper can be installed

up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-
center installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.

NOTE: 

If the hood is to be installed in a 

recirculating

,

non-vented ductless manner, order charcoal filters, 
kit number WB02X10707 for 30

hood models or 

kit number WB02X10708 for 36

hood models. 

These kits can be ordered from your GE supplier. 

Skip to Step 12 D and proceed

.

Содержание JV536

Страница 1: ...nstructions Charcoal Filters 5 Grease Filters 4 Hood Lights 5 Hood Surfaces 5 Stainless Steel Surfaces 5 Vent Controls 4 Installation Instructions 6 14 Consumer Support Product Registration 2 Consumer...

Страница 2: ...label on the back wall of the hood Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty If you do need service you can relax kn...

Страница 3: ...where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO REDUCE THE RISK OF A RANGE TOP...

Страница 4: ...reusable grease filters The metal filters trap grease released by foods on the cooktop They also help prevent flaming foods on the cooktop from damaging the inside of the hood For this reason the fil...

Страница 5: ...mum 50 watts Purchase and install PAR20 50 W Maximum halogen bulbs When replacing a bulb let it cool first Make sure that power to the light has been turned off Never allow a hot bulb to come into con...

Страница 6: ...ength of a 31 4 x 10 rectangular 6 or 7 diameter round duct should not exceed 65 equivalent feet NOTE It s important that ducting be installed using the most direct route and with as few elbows as pos...

Страница 7: ...nd Equivalent Length in Feet 0 25 50 75 100 125 150 31 4 x 10 Rectangular Transition to 6 Round 4 5 ft 7 Round 90 Elbow 8 ft 7 Roof Cap 30 ft 400 350 300 250 200 Air Volume in CFM 31 4 x 10 Rectangula...

Страница 8: ...GTH DUCT EQUIVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 34 Ft x Ft wall cap 6 ft w o with damper x Ft damper 6 Round 30 Ft x Ft roof cap 6 Round 5 5 Ft x Ft to 31 4 x 10 rect transition 6 Round...

Страница 9: ...o gain access to the parts MOUNTING SPACE NOTES This range hood is for installation over ranges up to 36 wide If you are going to vent your range hood to the outside see the Ducting Requirements secti...

Страница 10: ...e If the hood is to be installed in a recirculating non vented ductless manner do not knock out any vent openings in the hood Only an electrical access hole will be knocked out of the hood NOTE Only J...

Страница 11: ...screws REMOVE OTHER EXHAUST ADAPTOR Remove the 31 4 x 10 rectangular exhaust adaptor from inside the hood Set it aside along with its mounting screws and parts bag Depending on the model the exhaust...

Страница 12: ...mper flap Up to 1 side to side adjustment Tape Top back edge Exhaust adaptor damper vertical discharge position shown Pivot FOR 7 ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Re install the 7 ro...

Страница 13: ...INETS ONLY RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes NOTE DO NOT turn the power on until installation is complete...

Страница 14: ...SH ON FAN BLADE Pushing on the blade may cause it to interfere with other hood parts FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes NOTE Th...

Страница 15: ...uct not accessible to provide required service What GE Will Not Cover This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If...

Страница 16: ...cial discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be t...

Отзывы: