– 32 –
POWER MONITOR ERROR CODES
During Power-Up (occur
s
only during power-up)
Normal Power–
L1-L2
L1-N
No message
>150VAC
>90VAC AND <150VAC
SUPPLY OPEN
L1-L2
L1-N
NEUTRAL
NA
<90VAC
SUPPLY
L1-L2
L1-N
MISWIRED
<90VAC
>90VAC AND <150VAC
L1-L2
L1-N
NA
>150VAC
SENSE 120V
L1-L2
L1-N
ENTERING
>90VAC and <150VAC
>90VAC AND <150VAC
SALES MODE
After Power-Up (can occur anytime during operation)
Normal Power–
L1-L2
L1-N
No message
NA
>90VAC AND <150VAC
SUPPLY OPEN
L1-L2
L1-N
NEUTRAL
NA
<90VAC
SUPPLY
L1-L2
L1-N
MISWIRED
NA
>150VAC
LOW POWER
L1-L2
L1-N
<150VAC
NA
Note:
Low Power supersedes Supply Open Neutral
WARNING
: To prevent electrical shock, use
extreme caution when diagnosing oven with
outer covers removed and power on. The
high voltage circuit of the magnetron power
area (HVT, capacitor, diode, magnetron) is
4400V potential with respect to ground. Wait
at least 5 minutes after disconnecting
power before servicing the magnetron
power area.
WARNING:
Heat sinks on main power
board are electrically live. Take special
precautions when troubleshooting the main
power board with power on. If the main
power board has failed, the board capacitor
can hold a voltage charge on the heat sinks.
Wait at least 5 minutes after disconnecting
power before servicing the main power
board.
Diagnostics and Service Information
Содержание JS998 Series
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 43: ... 43 Single Wall Oven and Double Wall Oven Models Slide In Models ...
Страница 47: ... 47 ...
Страница 49: ... 49 ...
Страница 63: ... 63 ...
Страница 71: ... 71 Double Wall Oven 2 or 3 ...
Страница 72: ... 72 Double Wall Lower Oven 3 of 3 ...
Страница 73: ... 73 Slide In Range Current Limit Board 1 of 3 ...
Страница 74: ... 74 Slide In Range 2 of 3 ...
Страница 75: ... 75 Slide In Range 3 of 3 ...
Страница 76: ...Single Wall Oven 1 of 2 ...
Страница 77: ...Single Wall Oven 2 of 2 ...