2

Installation Instructions

FOR YOUR SAFETY

For Personal Safety, remove house fuse 
or open circuit breaker before beginning
installation. Failure to do so could result 
in serious injury or death.

Be sure your cooktop is installed properly
by a qualified installer or service technician.

To eliminate the risk of burns or fire due 
to reaching over heated surface elements,
cabinet storage located above the surface
units should be avoided. If cabinet storage
space is to be provided, the risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5

beyond the bottom of the cabinets. Cabinet
installation above the cooktop may be no
deeper than 13

.

Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 200°F) generated 
by the cooktop.

The cooktop should be easy to reach and
lighted with natural light during the day.

Always disconnect the electrical service to
the cooktop before repairing or servicing
the cooktop. This can be done by
disconnecting the fuse or circuit breaker.
Failure to do this could result in a
dangerous or fatal shock. Know where your
main disconnect switch is located. If you do
not know, have your electrician show you.

IMPORTANT SAFETY INSTRUCTIONS

ELECTRICAL REQUIREMENTS

This appliance must be supplied with the
proper voltage and frequency, and connected
to an individual, properly grounded branch
circuit, protected by a circuit breaker or a
time delay fuse as noted on rating plate. 

We recommend you have the electrical wiring
and hookup of your cooktop connected by a
qualified electrician. After installation, have
the electrician show you where your main
cooktop disconnect is located.

Wiring must conform to National Electrical
Code. You can get a copy of the National
Electrical Code, ANSI/NFPA No. 70-Latest
Edition, by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA  02269

The cooktop conduit wiring is approved for
copper wire connection only, and if you have
aluminum house wiring, you must use
special UL approved connectors for joining
copper to aluminum.

You must use a two-wire, three conductor
208/240 VAC, 60 Hertz electrical system. A
white (neutral) wire is not needed for this
unit. The cooktop must be installed in a
circuit that does not exceed 125 VAC nominal
to ground.

Refer to the rating plate on your cooktop for
the KW rating for your cooktop.

Содержание JP950

Страница 1: ...ered under the Warranty WARNING This appliance must be properly grounded ATTENTION INSTALLER ALL COOKTOPS MUST BE HARD WIRED DIRECT WIRED INTO AN APPROVED JUNCTION BOX A PLUG AND RECEPTACLE IS NOT PER...

Страница 2: ...erous or fatal shock Know where your main disconnect switch is located If you do not know have your electrician show you IMPORTANT SAFETY INSTRUCTIONS ELECTRICAL REQUIREMENTS This appliance must be su...

Страница 3: ...cooktop Refer to section on electrical requirements When installing your cooktop in your home make sure all local codes and ordinances are followed exactly as stated Make sure the wall coverings coun...

Страница 4: ...n withstand heat up to 200 F generated by cooktop 5 13 MAX Depth of uprotected overhead cabinets 30 MIN Clearance from countertop to unprotected overhead surface 2 MIN Clearance from cutout to side wa...

Страница 5: ...Lay the cooktop upside down onto the protected surface 2 ATTACH FOAM TAPE Apply the foam tape around the outer edge of the glass Do not overlap the foam tape 3 LOCATE MOUNTING PARTS Remove the hold d...

Страница 6: ...o the cooktop Make final check that all required clearances are met 6 INSTALLING THE COOKTOP CONT ATTACH HOLD DOWN BRACKETS TO CABINET Open the cabinet door and screw the hold down brackets to the cab...

Страница 7: ...ctrical Code will not permit grounding through neutral If used in new construction after January 1 1996 or in a mobile home recreational vehicle or if local codes do not permit grounding through the n...

Страница 8: ...oting list NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures mu...

Отзывы: