background image

8

Installation Instructions

PRE-TEST CHECKLIST

Remove all protective film, if present,
and any stickers.

Check to be sure that all wiring is secure
and not pinched or in contact with
moving parts.

Check level of appliance.

Check that the cooktop is properly
grounded.

D

C

B

A

1

CHECKLISTS

OPERATION CHECKLIST

Remove all items from the top 
of the cooktop surface.

Turn on the power to the cooktop.
(Refer to your Owner’s Manual.) Verify
that all surface burners operate properly.

Check that the circuit breaker is not
tripped nor the house fuse blown.

Check that conduit is securely connected
to the junction box.

See Owner’s Manual for 
troubleshooting list.

NOTE TO ELECTRICIAN:

The power leads supplied with this appliance
are UL recognized for connections to larger
gauge household wiring. The insulation of
these leads is rated at temperatures much
higher than the temperature rating of
household wiring. The current carrying
capacity of a conductor is governed by the
wire gauge and also the temperature rating
of the insulation around the wire.

NOTE: ALUMINUM WIRING

WARNING:
IMPROPER CONNECTION OF ALUMINUM
HOUSE WIRING TO THE COPPER LEADS
CAN RESULT IN A SERIOUS PROBLEM.

Splice copper wires to aluminum wiring
using special connectors designed and
UL approved for joining copper to
aluminum and follow the manufacturer’s
recommended connector procedure
closely.

NOTE: Wire used, location and enclosure of
splices, etc., must conform to good wiring
practice and local codes.

E

D

C

B

A

2

Содержание JP950

Страница 1: ...ered under the Warranty WARNING This appliance must be properly grounded ATTENTION INSTALLER ALL COOKTOPS MUST BE HARD WIRED DIRECT WIRED INTO AN APPROVED JUNCTION BOX A PLUG AND RECEPTACLE IS NOT PER...

Страница 2: ...erous or fatal shock Know where your main disconnect switch is located If you do not know have your electrician show you IMPORTANT SAFETY INSTRUCTIONS ELECTRICAL REQUIREMENTS This appliance must be su...

Страница 3: ...cooktop Refer to section on electrical requirements When installing your cooktop in your home make sure all local codes and ordinances are followed exactly as stated Make sure the wall coverings coun...

Страница 4: ...n withstand heat up to 200 F generated by cooktop 5 13 MAX Depth of uprotected overhead cabinets 30 MIN Clearance from countertop to unprotected overhead surface 2 MIN Clearance from cutout to side wa...

Страница 5: ...Lay the cooktop upside down onto the protected surface 2 ATTACH FOAM TAPE Apply the foam tape around the outer edge of the glass Do not overlap the foam tape 3 LOCATE MOUNTING PARTS Remove the hold d...

Страница 6: ...o the cooktop Make final check that all required clearances are met 6 INSTALLING THE COOKTOP CONT ATTACH HOLD DOWN BRACKETS TO CABINET Open the cabinet door and screw the hold down brackets to the cab...

Страница 7: ...ctrical Code will not permit grounding through neutral If used in new construction after January 1 1996 or in a mobile home recreational vehicle or if local codes do not permit grounding through the n...

Страница 8: ...oting list NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures mu...