If NO Convection element function, with
power removed, (LOTO) check resistance
from PR wire on RLY500A to BLUE wire on
RLY502A should be approx. 35-40 Ω If ok,
check between PR on RLY500A to O on
RLY540 should be approx. 15 Ω If ∞ (open)
suspect HIGH LIMIT is open. Unit should
also have no BROIL function if HIGH LIMIT
is open.