44
GE Title or job number
11/26/2013
Cooling fans
T012 ERC f-codes
F96 thru F99
F96 indicates the UPPER fan is running slow.
F97 indicates the LOWER fan is running slow.
F98 indicates the UPPER fan is running too fast.
F99 indicates the LOWER fan is running too fast.
The DC supply voltage to cooling fan boards can be checked on ERC at CN300 pin 1 W to pin 7
BK. Feedback will be checked from pin 7 of CN300 BK to pin 1 of CN700 Bu for UPPER.
LOWER will be checked from pin 7 of CN300 BK to pin 3 of CN700 PR.
Содержание JK1000
Страница 3: ...3 GE Title or job number 11 26 2013 ...
Страница 17: ...17 GE Title or job number 11 26 2013 SWO install instructions wall and under counter ...
Страница 18: ...18 GE Title or job number 11 26 2013 DWO installation dimensions and rail install directions ...
Страница 31: ...31 GE Title or job number 11 26 2013 F Codes T09 Back to T of C ...
Страница 47: ...47 GE Title or job number 11 26 2013 Troubleshooting all AC circuits Only in circuit for end of line test ...
Страница 55: ...55 GE Title or job number 11 26 2013 Lower oven relay board daughter Back to definitions ...
Страница 81: ...81 GE Title or job number 11 26 2013 Notification LED boards Back to Definitions Back to T of C ...
Страница 82: ...82 GE Title or job number 11 26 2013 Oven sensor note be sure to reinstall insulation piece behind bracket ...
Страница 84: ...84 GE Title or job number 11 26 2013 Hidden bake part 2 ...
Страница 86: ...86 GE Title or job number 11 26 2013 Hidden bake bottom view ...