Document 8600092587P r04 2019 May
21
Integritas Wall Mount Charger
-
Quick Start Guide
Parts List
continued
Specifications and Application
•
External Surge Protective Device (SPD) is required on all AC inputs.
•
Equipment Safety is Approved in UL1449/IEC 60664
-
1 Installation Category II environments for ambient temperature up to 50°C.
Models using IP020ACR125ATEZ rectifiers:
For input voltages above 266V, the maximum output current and power are de
-
rated by 2.8% per °C for operating ambient above 40°C.
•
Equipment and subassembly ports:
1. are suitable for connection to intra
-
building or unexposed wiring or cabling;
2. can be connected to shielded intra
-
building cabling grounded at both ends.
•
Grounding / Bonding Network –
Connect to an Isolated Ground Plane (Isolated Bonding Network) or an Integrated Ground Plane (Mesh
-
Bonding Network or Common Bonding Network).
•
Installation Environment
-
Install where NEC applies.
Reference Documents
These documents are available at
Document
Title
8600092588P
Pulsar XL Product Manual
850049786
Pulsar Plus Controller Family Troubleshooting
GE
601
Shiloh Rd.
Plano, TX 75074
1
-
972
-
244
-
9288
www.gecriticalpower.com
© 2017 General Electric Company. All rights reserved.
Thermal Probes
Comcode
Description
Application
1600093512A
DTP873_AMBIENT
Ambient Thermal Probe Kit
1600093513A
DTP873_BATTERY
Battery Terminal Thermal Probe Kit
Additional Accessories (Mounting Hardware, Filters, etc.)
Comcode
Description
Application
1600097831A
19IN IWC 19IN FRAME MOUNT KIT
Mounting hardware to attach 19" Battery Charger to 19" Frame
1600097832A
19IN IWC 23IN FRAME MOUNT KIT
Mounting hardware to attach 19" Battery Charger to 23" Frame
850052732
FILTER, WALL BOX, 19"
Air Filter for 19" Battery Charger cabinet
850053032
FILTER, WALL BOX, 23"
Air Filter for 23" Battery Charger cabinet
4600097827P
VAL
-
CP
-
350
-
ST 2859602
AC Line Surge Arrestor Replacement Module
4600097268P
VAL
-
CP
-
N/PE
-
350
-
ST 2859699
AC N
-
PE Surge Arrestor Replacement Module
4600097830P
PST
-
SEC
-
T3
-
24P 2905232
24V DC Surge Arrestor Replacement Module
4600219078P
VAL
-
US
-
600D/30/P
-
2910341
Type 2
600 V AC Plug For 3
-
phase DELTA Surge Protection Device
4600097829P
PST
-
SEC
-
T3
-
60P 2905233
48V DC Surge Arrestor Replacement Module
4600097828P
PST
-
SEC
-
T3
-
230P 2905235
125V DC Surge Arrestor Replacement Module