INSTALLATION AND OPERATION
SX TRANSISTOR CONTROL
Page
17
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-08
Accelerator voltage input is too high on
power up after initial key switch
closure.
This status code will be displayed when the
accelerator input voltage at P7 >0.9V when the
battery plug or key switch is opened and closed.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate
POSSIBLE CAUSE
Accelerator input is mis-adjusted or
defective.
•
Input voltage at P7 should be less than
0.9 volts. Adjust or replace accelerator
unit to insure that the voltage at P7 is less
than 0.9 volts before depressing pedal.
Open circuit at P8 or open potentiometer
wiper at P7 – verify continuity of wiring at
both points.
L
P9 P7
P8
P1
P17
P2
P6
P4
P5
TURF SW.
FORW
ARD SW
.
REVERSE SW
.
ACC POT
TACHOMETER
P15 P14 P16
P10
BU
ZZER
RED
GREEN
BLACK
P12
RE
G
E
N
B
R
AKE SW
P21
MO
T
O
R
OV
E
R
TEMP
+72V
+72V
+72V
+72V
+72V +72V
+72V
P22
P23
P20
RS232
72V
NEG
P3
NEG IN
PU
T
STA
R
T
SW
.
+72V
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-09
Both the forward and reverse switches or
the turf and reverse switches are closed at
the same time.
This status code will be displayed when P4 and
P5 or P6 and P5 are greater than 50% of battery
volts.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Forward or reverse or turf switch welded closed
or mis-adjusted to be held closed.
•
Replace or adjust directional switches to insure
that they are open when switch is returned to
neutral or off.
Short circuit between battery positive and P4,P5
and/or P6.
•
Disconnect wires from P4, P6 and P5 and
check wire for short circuit to positive side of
directional switch
Defective control.
•
Disconnect wires and measure voltage at P4,
P6 and P5. Voltage should be less than 50%
of battery volts, if not, replace control.
L
P9 P7
P8
P1
P17
P2
P6
P4
P5
TU
RF SW
.
FORWARD S
W
.
R
E
VERSE
SW
.
ACC POT
TACHOMETER
P15 P14 P16
P10
BUZZER
RED
GREEN
BLAC
K
P12
REGEN
BR
AK
E
SW
P21
MO
T
O
R
OVER
TE
M
P
+72V
+72V
+72V
+72V
+72V +72V
+72V
P22
P23
P20
RS232
72V
NEG
P3
NE
G
IN
P
U
T
START SW
.
+72V
Updated Sept 2019