ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
Page
45
March 2000
2
11.44
17
01.34
3
07.60
18
01.27
4
05.72
19
01.20
5
04.57
20
01.14
6
03.81
21
01.09
7
03.27
22
01.04
8
02.86
23
00.99
9
02.54
24
00.95
10
02.28
25
00.91
11
02.08
26
00.88
12
01.90
27
00.85
13
01.76
28
00.82
14
01.63
29
00.79
15
01.52
30
00.76
16
01.43
31
00.74
FUNCTION 15
BATTERY VOLTS
(Push l5)
This function allows for the adjustment of voltage range
for controls equipped with the Battery Discharge
Indication function. In order for the BDI to operate
properly, the setting as shown in the table must be entered:
Battery volts
Set units
24 volts
Between 0 and 31
36 volts
Between 32 and 44
48 volts
Between 45 and 69
72 volts
Between 70 and 80
80 volts
Between 81 and 183
36/48 volts
Between 184 and 250
No BDI
Between 251 and 255
FUNCTION 16
PEDAL POSITION PLUG
(Push CONT 1)
This function will allow the adjustment of the pedal
position plug range. Pedal position will reduce the
plugging current to the current value set by this function
as the accelerator is returned to the creep speed position.
Maximum plug current is obtained with the accelerator in
the top speed position.
Resolution
Example
Min
Max
Set
Per unit value If set at 20
26
226
0 to 255
0.78 amps
41.6 amps
55
455
0 to 255
1.57 amps
86.4 amps
55
655
0 to 255
2.35 amps
102 amps
To disable the pedal position plug function, adjust this
current value to the same current value as the plug
distance current.
Example: If plug distance current, Function 5, is set at 350
amps, then set pedal plug current at 350 amps. With this
setting, pedal position will have no effect on plugging
distance.
Note: Vehicles equipped with regenerative braking will
vary the regen current with pedal position. However,
minimum regen current is fixed at 50 amps. The pedal
position will vary regen current between 50 amps and the
maximum value of regen current set by Function 9.
FUNCTION 17
CARD TYPE SELECTION
( Push CONT 2 )
This function allows for the selection of the card type used
for your vehicle’s application. The table below shows the
setting to select card application type, depending on
which control card is used.
Note that the right (slave)
control for a dual motor proportioning system will be set
differently than the left (master) control.
Note: Non-Auto Plug/Regen logic cards must be used for
settings below:
Functions
Standard
Regen
Std C/L
0 to 4
40 to 44
Std C/L (Right)
64 to 68
104 to 108
High C/L
5 to 9
45 to 49
High C/L (Right)
69 to 73
109 to 113
Note: Auto Plug/Regen logic cards must be used for the
settings below:
Functions
Standard
Regen
Std C/L
Auto Plug
10 to 14
50 to 54
Std C/L
Auto Plug (Right)
74 to 68
114 to 118
High C/L
Auto Plug
15 to 19
55 to 59
High C/L
Auto Plug (Right)
79 to 83
119 to 123
Settings for these functions should be made within the
ranges indicated above.
Warning: These settings must be changed by authorized
personnel only, following instructions supplied by the
vehicle manufacturer. Card type selection must be made
within the capabilities of the control panel and the
supporting electromechanical devices. Failure to comply
with proper application standards could result in mis-
operation or damage to the controls and/or motors.
The following functions have function numbers larger
than the numbers on the Handset keyboard. To access
these functions. Push the CONT key and the number
shown in the following instructions at the same time.
THE SEAT SWITCH MUST BE OPEN.