DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
Page
30
March 2000
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-57
Controller “motor current sensor” input
too low during running.
This status code will be displayed when the voltage input
from the current sensor is too low during running.
MEMORY RECALL
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective control.
??
Replace controller unit.
FU3
FU5
KEY SWITCH
*
CONTROL
POWER
CONNECTION
POS
A1
NEG A2
ARMATURE
FU1
LINE
A2
A1
*
*
1A
*
OSC CARD CONNECTIONS
L
1A
DIRECT SW.
P18
P17
P2
P6
P4
SEAT SW.
*
SP
P3
*
FWD
REV
P5
*
ACCEL
START
SW.
P1 P7 P9
*
F1
F2
FIELD
F1
F2
ACCEL
START
SW.
+
-
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-64
The line driver input (P2-17) is less
than 12% of battery volts
This status code will be displayed when the control
detects that the line driver input (P2-17) is less than 12%
battery volts when the key switch is turned on.
MEMORY RECALL
NO
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
-Open wire connection to Pin 17
- Shorted line Driver transistor
Defective control.
??
Replace controller unit.
FU3
FU5
KEY SWITCH
*
CONTROL
POWER
CONNECTION
POS
A1
NEG A2
ARMATURE
FU1
LINE
A2
A1
*
*
1A
*
OSC CARD CONNECTIONS
L
1A
DIRECT SW.
P18
P17
P2
P6
P4
SEAT SW.
*
SP
P3
*
FWD
REV
P5
*
ACCEL
START
SW.
P1 P7 P9
*
F1
F2
FIELD
F1
F2
ACCEL
START
SW.
+
-