NE-M Installation Guide
H5692448
850050111
Issue 03 August 2017
51
Step
Action – Pulsar Plus
1
Analog Interface Connector
Connect and wire to shunt and alarms.
J1 is a 6-pin connector provided for analog interface to a plant shunt, distribution alarms, and open battery
string alarms. Typically, a factory installed plant wire harness plugs into this connector. This wire set has a
purple wire with a Faston
®
receptacle for connecting the Open String Alarm from field installed battery
disconnect breakers.
Table 4 Analog Interface Connector Signals – Pulsar Plus
Pin
Signal
1
Shunt+
2
Shunt Reference
3
Shunt-
4
Fuse Alarm Major +24V
5
Open String
6
Fuse Alarm Major -48V