32

REF. NO. 

PART NO. 

PART DESCRIPTION 

(01)

0002 

WS31X10051 

BACK COVER, ELECTRONICS

 

0003 

WS35X10001 

O-RING SEAL KIT 

0004 

WS34X10020 

DECAL, FACEPLATE 

0005 

WS07X10004 

HOSE, DRAIN, 20 FT. 

0007 

WS14X10002 

DISTRIBUTOR, TOP 

0008 

WS14X10005 

DISTRIBUTOR, BOTTOM 

0009 

WS01X10002

 

RESIN, 1 CU. FT. 

0010 

WS32X10030 

TANK, RESIN,

 

9 X 35

 

0011 

WS31X10052 

COVER, TOP 

0012 

WS34X10021 

FACEPLATE 

0013 

WS21X10053 

CONTROL 

0016 

WS26X10013 

EXTERNAL POWER SUPPLY WITH 

 

 

 

POWER CORD

 

0017 

WS31X10053 

COVER, SALT HOLE, WITH LABEL 

0019 

WS33X10010 

RIM 

0020 

WS31X10024

 

COVER, BRINEWELL 

0022 

WS34X10025

 

BRINEWELL 

0023 

WS02X10088 

SCREW KIT, BRINE TANK

 

0024 

WS32X10031 

TANK, BRINE 

0026 

WS22X10063 

OVERFlOW ADAPTER KIT

 

0029 

WS15X10077 

BRINE VALVE ASM. 

0030 

WS35X10063 

FlOAT, STEM & GUIDE 

0056 

WS28X10078 

TANK NECK CLAMP KIT

 

0103 

WS21X10003 

SWITCH 

0105 

WS02X10014 

SCREW

, #10 - 14 x 2”

 

0106 

WS31X20060

 

COVER, VALVE

 

0107 

WS03X10010 

WASHER WAVE

 

0108 

WS26X10002 

ROTOR & DISC ASM. 

0109 

WS19X10010 

CAP

 

0110 

WS03X10011 

SEAL, O-RING 

1.125 X 1.37

 

0111 

WS19X10005 

SUPPORT SCREEN 

0112 

WS03X10013 

SCREEN 

0113 

WS22X10036 

FlOW PLUG, .15 GPM

 

0114 

WS08X10008

 

GASKET, NOZZLE/VENT 

0115 

WS03X10073 

SCREEN CONE

 

0116 

WS22X10021 

PLUG, FILL FlOW, .30 GPM 

0117 

WS03X10017 

NUT FERRULE

 

0118 

WS15X10034 

NOZZLE/VENTURI BODY 

0119 

WS03X10018 

RETAINER 

:6;

6($/25,1*Ǝ;Ǝ

 

0121 

WS15X10010 

BODY, VALVE 

0122 

WS03X10020 

SPRING 

0123 

WS22X10022 

PLUG, DRAIN SEAL 

0124 

WS15X10046

 

NOZZLE/VENTURI ASM. 

0130 

WS35X10005 

SEAL KIT

 

0132 

WS22X10064 

DRAIN HOSE ADAPTER KIT

 

0136/140 

WS26X21822 

MOTOR, CAM & GEAR KIT, 3/4" 

0138 

WS26X20061 

MOTOR MOUNT

 

0141 

WS02X20063

6&5(:[Ǝ

 

0143 

WS60X10013 

ADAPTER—NPT THREADED—STD VALVE 

0145 

WS60X10004 

CLIP 

0146 

WS28X10017 

HARNESS WIRE, SENSOR ASSY

 

0147 

WS19X10006 

TURBINE & SUPPORT ASM.* 

0151 

WS15X21823 

BYPASS VALVE ASM.* 

0152 

WS03X10025 

SEAL, O-RING 

0998 

WS35X10064

 

INSTALLATION KIT 

0999 

 49-50282-8 

OWNER’S MANUAL 

1

* Includes 2 each of REF. NO. 152 (O-RING)

Parts List

GXSF30V

Содержание GXSF30V02

Страница 1: ...rol panel Model GXSF30V Systems tested and certified by NSF International against NSF ANSI Standard 44 for the chemical reduction claims specified on page 3 and certified to NSF ANSI 372 C USA R Syste...

Страница 2: ...fter the system WARNING Discard all unused parts and packaging material after installation Small parts remaining after the installation could be a choke hazard The water softening system works on 24 v...

Страница 3: ...efer to Cleaning Iron Out of the Water Softening System section Canada working pressure limits 1 4 7 0 kg cm2 This model is efficiency rated The efficiency rating is valid only at the minimum stated s...

Страница 4: ...oned However you should avoid using HOT water because the water heater will fill with the hard water FILL Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin...

Страница 5: ...g system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for 24 hours When power is restored you have to reset the present time only...

Страница 6: ...e It appears as small cloudy yellow orange or reddish suspended particles After the water stands for a period of time the particles settle to the bottom of the container Generally these irons are remo...

Страница 7: ...sure all the parts shown below are present Additional parts must be purchased to complete the installation Thoroughly check the water softener for possible shipping damage and parts loss Also inspect...

Страница 8: ...n over current device such as a circuit breaker or fuse Always install the water softener between the water inlet and water heater Any other installed water conditioning equipment should be installed...

Страница 9: ...the length needed Flexible drain hose is not allowed in all localities check your plumbing codes If local codes do not allow use of a flexible drain hose a rigid valve drain run must be used Purchase...

Страница 10: ...e bypass valve Soldering heat will damage the adaptors and valve WARNING A copper or galvanized cold water pipe may be used to ground electrical outlets in the home Failure to maintain this ground pat...

Страница 11: ...ot included Pipe 1 1 2 air gap Floor Drain Secure Valve Drain Hose in place over Floor Drain Salt Storage Tank Overflow Hose Overflow Drain Elbow Conditioned Water To Outside Faucets Plug in Power Sup...

Страница 12: ...from the top down see Figure 7 and 10 IMPORTANT Be sure the clips snap firmly into place so the single bypass valve will not pull out MOVE WATER SOFTENER INTO PLACE WARNING Excessive Weight Hazard Use...

Страница 13: ...er installation do all sweat soldering before connecting pipes to the NPT adapters and bypass valve Torch heat will damage plastic parts WARNING If solder is used to make pipe connection use only lead...

Страница 14: ...EST FOR LEAKS To prevent air pressure in the water softener and plumbing system complete the following steps in order 1 Fully open two or more softened cold water faucets close to the water softener l...

Страница 15: ...oned To have fully conditioned hot water immediately wait until the initial recharge is over Then drain the water heater following instructions for water heater until water runs cold WARNING Discard a...

Страница 16: ...ept changes A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the button you h...

Страница 17: ...laboratory to request a water hardness test kit at 1 800 949 8220 Option 4 If your report shows hardness in parts per million ppm or milligrams per liter mg l simply divide by 17 1 to get the equivale...

Страница 18: ...ay provide erratic operation For example the blue indicator light may flash showing that more salt is required when the actual salt level in the tank is well above the Level 0 In some cases the DAYS T...

Страница 19: ...ll provide the most efficient usage of water but may use more salt The degree of difference between these two cycles is highly dependent on the water usage and hardness at a particular installation NO...

Страница 20: ...s and Err is in the display electrical problem with system see page 25 LOW SALT SIGNAL When the DAYS TO EMPTY drops to 15 the blue indicator light and DAYS TO EMPTY in the display will flash every sec...

Страница 21: ...rrosive fumes that weaken and shorten the life of some water softening system parts CLEANING IRON OUT OF THE WATER SOFTENING SYSTEM Your water softening system takes hardness minerals calcium and magn...

Страница 22: ...le and venturi Wash and rinse the parts in warm water until clean If needed use a small brush to remove iron or dirt Also check and clean the gasket NOTE Some models have a small flow plug located in...

Страница 23: ...e is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and carefully push it down into the s...

Страница 24: ...r if the tank is empty refill with recommended salt Press for 3 seconds the RECHARGE button to start an immediate recharge and restore soft water supply External power supply unplugged at wall outlet...

Страница 25: ...s it the abrasive feel you may have been accustomed to The slippery feel is the clean feel of soft water Water Softener not using any salt Water softening system is a demand unit Does not use much sal...

Страница 26: ...Sanitization Procedures At completion of recharge cycle approx 2 hours run water from faucets to purge the salty water Low water pressure Check pressure Drain height 8 or less pressure should be minim...

Страница 27: ...ow to further isolate the problem Procedure for removing error code from display 1 Unplug transformer from electrical outlet 2 Correct problem 3 Plug in transformer 4 Wait 8 minutes The error code wil...

Страница 28: ...lectrical power applied b Press the DOWN button to display the number of regenerations initiated by the electronic control since the code number was entered 6 Press and hold the MODE SET button until...

Страница 29: ...e and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and ventu...

Страница 30: ...30 8 7 6 5 11 16 146 5 999 29 4 12 2 13 3 7 8 9 10 56 56 17 19 20 22 23 23 24 30 26 Exploded View...

Страница 31: ...31 Cross section View Seal Wear Strip 124 109 110 111 112 113 114 116 115 117 118 120 119 146 106 105 103 130 107 108 130 121 147 152 122 123 130 151 130 132 136 140 138 141 145 Exploded View...

Страница 32: ...COVER VALVE 1 0107 WS03X10010 WASHER WAVE 1 0108 WS26X10002 ROTOR DISC ASM 1 0109 WS19X10010 CAP 1 0110 WS03X10011 SEAL O RING 1 125 X 1 37 1 0111 WS19X10005 SUPPORT SCREEN 1 0112 WS03X10013 SCREEN 1...

Страница 33: ...n Authorized GE Appliances Service location for service In Alaska the limited warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation...

Страница 34: ...y is extended to the original purchaser for products purchased for home use within Canada In home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to prov...

Страница 35: ...nimum Buyer Renter ______________________________________________ Date _______________ Seller ____________________________________________________ Date _______________ Seller s Address________________...

Страница 36: ...ded warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your warra...

Страница 37: ...para los reclamos sobre reducci n de qu micos especificados en la p gina 39 y certificados para NSF ANSI 372 C USA R Sistema probado y certificado por Water Quality Association en cumplimiento con CSA...

Страница 38: ...erci rese de usar exclusivamente el transformador incluido El transformador se debe conectar nicamente a un tomacorriente interior con conexi n a tierra de 120 voltios Utilice nicamente sales para des...

Страница 39: ...sulte la secci n Limpieza del Hierro con el Sistema Suavizante de Agua L mites de presi n en Canad 1 4 7 0 kg cm2 Este modelo cuenta con una calificaci n de eficiencia El ndice de eficiencia es v lido...

Страница 40: ...E debido a que el calentador de agua se llenar con el agua dura LLENADO La sal disuelta en agua es llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas part cula...

Страница 41: ...una recarga de inmediato y al finalizar en unas dos horas contar con un nuevo suministro de agua suave Una vez iniciada ya no podr cancelar esta recarga FUNCI N MEMORIA Si el suministro el ctrico del...

Страница 42: ...rt culas turbias suspendidas de color amarillo anaranjado o rojizo Una vez que el agua se asent por un per odo de tiempo las part culas quedan en el fondo del envase Generalmente estos hierros son eli...

Страница 43: ...o Dos llaves ajustables 2 accesorios para conectar la tuber a de su residencia a las roscas hembras NPTF de 2 5 cm 1 en el alojamiento del filtro Es posible que se necesite partes adicionales para com...

Страница 44: ...disyuntor o fusible Siempre instale el suavizante de agua entre la entrada de agua y el calentador de agua Cualquier otro equipamiento para el acondicionamiento de agua deber a ser instalado entre la...

Страница 45: ...o est permitido en todas las localidades consulte sus c digos de plomer a Si los c digos locales no permiten el uso de una manguera de drenaje flexible se deber usar un drenaje con v lvula r gida Adqu...

Страница 46: ...dores y la v lvula ADVERTENCIA Una tuber a de cobre o galvanizada de agua fr a podr a usarse para conectar a tierra los tomacorrientes el ctricos en la casa No mantener esta conexi n a tierra podr a r...

Страница 47: ...dor de Transpiraci n NPT de 1 no incluido Tuber a 1 1 2 air gap Drenaje por Suelo Secure Valve Drain Hose in place over Floor Drain Manguera de Desborde del Salmuera Tanque Adaptador para Desbordes Ag...

Страница 48: ...cia abajo consulte las Figuras 7 y 10 IMPORTANTE Aseg rese de que las abrazaderas queden firmes de modo que la v lvula de desviaci n simple no se suelte MUEVA EL SUAVIZANTE DE AGUA A SU LUGAR ADVERTEN...

Страница 49: ...desviaci n El calor de la linterna da a las partes pl sticas ADVERTENCIA Si se har n soldaduras para la conexi n de las tuber as use s lo soldadoras y fundidores libres de plomo para evitar el envenen...

Страница 50: ...e agua a la manguera de desborde del tanque de almacenamiento de sal PRUEBA DE P RDIDAS Para evitar la presi n de aire en el suavizante de agua y en el sistema de plomer a complete los siguientes paso...

Страница 51: ...on agua caliente acondicionada de forma inmediata espere hasta que la recarga inicial est terminada Luego drene el calentador de agua siguiendo instrucciones para el calentador de agua hasta que el ag...

Страница 52: ...tido suena al presionar los botones para la programaci n del control Un pitido se ala un cambio en la pantalla de control Pitidos repetidos indican que el control no aceptar un cambio desde el bot n q...

Страница 53: ...un kit de evaluaci n de la dureza del agua al 1 800 949 8220 Opci n 4 Si su informe muestra una dureza en partes por mill n ppm o miligramos por litro mg l simplemente divida esto por 17 1 para obtene...

Страница 54: ...emanas de funcionamiento DAYS TO EMPTY D as Hasta Vaciarse podr tener un funcionamiento err tico Por ejemplo la luz Indicadora azul podr titilar mostrando que se necesita m s sal cuando el nivel de sa...

Страница 55: ...o es posible que se use m s sal El grado de diferencia entre estos dos ciclos es altamente dependiente del uso y el nivel de dureza del agua en una instalaci n particular NOTA Las Regulaciones de Cali...

Страница 56: ...ra La luz titila y Err aparece en la pantalla problema el ctrico con el sistema SE AL DE NIVEL DE SAL BAJO Cuando la funci n DAYS TO EMPTY D as Hasta Vaciarse cae a 15 la luz azul indicadora y DAYS TO...

Страница 57: ...bi n puede liberar gases corrosivos que debilitan y acortan la vida til de algunas partes del sistema suavizante de agua LIMPIEZA DEL HIERRO DEL SISTEMA SUAVIZANTE DE AGUA Su sistema suavizante de agu...

Страница 58: ...t n limpias De ser necesario use un pincel peque o para retirar el hierro o la suciedad Tambi n controle y limpie la junta NOTA Algunos modelos cuentan con un enchufe de flujo peque o ubicado en la bo...

Страница 59: ...st debajo de sta La siguiente es la mejor forma de controlar la formaci n de un puente de sal La sal deber a estar suelta hasta el fondo del tanque Tome un mango de escoba o una herramienta similar y...

Страница 60: ...ga para comenzar una recarga de inmediato y restablecer el suministro de agua suave Suministro de corriente externa desenchufado del tomacorriente de pared o el cable de corriente no est conectado al...

Страница 61: ...La sensaci n resbalosa es la sensaci n pura del agua suave Consulte la secci n Ajuste de la Dureza del Agua Suavizante de Agua sin uso de sal El sistema suavizante de agua es una unidad de demanda No...

Страница 62: ...n Al completar el ciclo de recarga aprox 2 horas deje correr el agua en los grifos para purgar el agua salada Presi n baja del agua Controle la presi n Altura del drenaje de 8 o menos la presi n debe...

Страница 63: ...a n m s el problema Procedimiento para eliminar el c digo de error de la pantalla 1 Desenchufe el transformador del tomacorriente el ctrico 2 Corrija el problema 3 Enchufe en el transformador 4 Esper...

Страница 64: ...s iniciadas por el control electr nico desde que el c digo num rico fue ingresado 6 Mantenga presionado el bot n MODE SET Modo Configuraci n hasta que el c digo del modo F30 para GXSH30V aparezca en l...

Страница 65: ...do y Limpieza del Sistema Suavizante de Agua Si el sistema suavizante de agua no hace que ingrese salmuera controle Suciedad o defectos en la boquilla y o el venturi Defecto en el sellado de la boquil...

Страница 66: ...66 Vista Expandida 8 7 6 5 11 16 146 5 999 29 4 12 2 13 3 7 8 9 10 56 56 17 19 20 22 23 23 24 30 26...

Страница 67: ...67 Vista Expandida Cross section View Seal Wear Strip 124 109 110 111 112 113 114 116 115 117 118 120 119 146 106 105 103 130 107 108 130 121 147 152 122 123 130 151 130 132 136 140 138 141 145...

Страница 68: ...WS03X10010 ARANDELA ONDULADA 1 0108 WS26X10002 ENSAMBLE DE ROTOR Y DISCO 1 0109 WS19X10010 TAPA 1 0110 WS03X10011 SELLO ANILLO O 1 125 X 1 37 1 0111 WS19X10005 PANTALLA DE SOPORTE 1 0112 WS03X10013 PA...

Страница 69: ...ue traiga el producto a una Ubicaci n del Servicio T cnico de GE Appliances Autorizado para recibir el servicio En Alaska la garant a excluye el costo de env o o llamadas del servicio a su hogar Algun...

Страница 70: ...electr nico si fallara debido a un defecto en los materiales o la fabricaci n Durante esta garant a limitada de tres a os usted ser responsable por cualquier trabajo o costos relacionados con el servi...

Страница 71: ...un m nimo de 2 a os Comprador Arrendatario_____________________________________ Fecha ______________ Vendedor _________________________________________________ Fecha ______________ Domicilio del Vend...

Страница 72: ...uentos especiales que est n disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de GE Appliances a n estar n all cuando su garant...

Отзывы: