background image

9

Installation Instructions

C

H

HOT

HOT

HOT

HOT

COLD

COLD

COLD

COLD

CONNECTING THE WASHER

If not installed, install rubber washer in one end of hot 

water hose. Thread hot water hose onto connection 

labeled 

H

 at top rear of washer. Hand tighten, plus an 

additional 1/8 turn with pliers.
If not installed, install rubber washer in one end 

of cold water hose. Thread cold water hose onto 

connection labeled 

C

 at top rear of washer. Hand 

tighten, plus an additional 1/8 turn with pliers.

leaving room for you to make water, drain, electrical 

and vent connections to your home.

NOTE:

 If longer drain 

hose is required, order 

drain hose extension kit, 

part number WH49X301. 

Connect additional drain 

hose (contained in kit) to 

original hose with hose 

clamp (contained in kit).
Insert free end of drain 

hose into drain opening 

of your home up to drain 

hose stopper (do not 

remove hose stopper it 

prevents siphoning). If 

water valves and drain 

are built into wall, fasten 

drain hose to one of 

water hoses with cable 

tie provided (ribbed side 

on inside). If your drain is 

a standpipe, fasten drain 

hose to standpipe with 

cable tie provided.

WATER SUPPLY REQUIREMENTS

•  HOT AND COLD WATER FAUCETS – Must 

be within 42” of the appliance water inlet hose 

connections. The faucets must be 3/4” garden 

hose-type so inlet hoses can be connected.

•  WATER PRESSURE – Must be between 20 and 

120 pounds per square inch with a maximum 

unbalance pressure, hot vs. cold flowing, of 10 

pounds per square inch.

•  WATER TEMPERATURE – Water heater should be 

set to deliver 120°F (50°C) to 150°F (66°C) in the 

washer when HOT wash is selected.

•  SHUT-OFF VALVES – Both hot and cold water 

shut-off valves (faucets) should be supplied.

•  LOCATION – Do not install appliance in an area 

where the temperature will fall below freezing. 

If appliance is stored or transported in freezing 

temperatures, be sure all water from the fill and 

drain systems has been removed.

DRAIN REQUIREMENTS

•  DRAIN RATE – The drain or standpipe must be 

capable of accepting a discharge at the rate of 16 

gallons per minute.

•  DRAIN HEIGHT – The drain height must be 30” 

minimum and 96” maximum.

•  STANDPIPE DIAMETER – The standpipe diameter 

must be 1-1/2” minimum. There MUST be an air 

gap around the drain hose in the standpipe. A snug 

fit can cause a siphoning action.

•  SIPHON BREAK – For a drain facility less than 30” 

high, the hose, coupling and clamps provided in the 

machine must be used and, in addition, a siphon break 

MUST be installed on the back of the machine. Obtain 

and use a siphon break kit and follow the instructions 

in the kit.

PLUMBING INFORMATION

CONNECTING TO PLUMBING 

FACILITIES

Содержание GUD57EEMTDG

Страница 1: ...ions BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all governing codes and ordinances Insta...

Страница 2: ...ing material carton from the appliance UNPACKING YOUR APPLIANCE 2 Remove the bag containing the washer hoses and parts from tub NOTE With feet set at mid position feet can be adjusted 3 8 Dimension re...

Страница 3: ...other surfaces is 0 either side 0 rear 1 front 1 top Consideration must be given to provide adequate clearance for installation and service Closet doors must be louvered or otherwise ventilated and do...

Страница 4: ...s a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and...

Страница 5: ...nada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance...

Страница 6: ...elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcula...

Страница 7: ...uld require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best...

Страница 8: ...ty hazard 27 MODELS ONLY BOTTOM OR SIDE VENTING For Downward Venting Insert elbow rotate it so that it points downward and connect it to the dryer s internal duct Use only 4 UL approved rigid metal fo...

Страница 9: ...he appliance water inlet hose connections The faucets must be 3 4 garden hose type so inlet hoses can be connected WATER PRESSURE Must be between 20 and 120 pounds per square inch with a maximum unbal...

Страница 10: ...n its final position place a level on top of back part of the washer lid and check it side to side then check front to back Screw the front leveling legs up or down to ensure the appliance is resting...

Страница 11: ...age de l inspecteur lectrique local IMPORTANT Observez toutes les r glementations et ordonnances en vigueur Installez la appareil conform ment aux instructions du fabricant et aux r glementations loca...

Страница 12: ...e D BALLAGE DE VOTRE APPAREIL Enlevez le sac contenant les tuyaux de jonction et les pi ces du bac 3 27 DIMENSIONS NOMINALES DU PRODUIT NOTE Dimensions en pieds correspondant 3 8 S CHEUSES GAZ SEULEME...

Страница 13: ...Il faut veiller procurer le d gagement n cessaire l installation et aux interventions de service Les portes du placard doivent tre perfor es ou autrement ventil es et doivent contenir un minimum de R...

Страница 14: ...risque de choc lectrique en procurant un circuit de moindre r sistance au courant lectrique Cet appareil utilise un cordon dot d un conducteur de mise la terre de l appareillage et d une fiche de mise...

Страница 15: ...bject doivent tre utilis s vitez de faire reposer le conduit sur des objets coupants Pour une meilleure efficacit de s chage 1 Glissez une des extr mit s du conduit par dessus le conduit de sortie de...

Страница 16: ...its du nombre de tours du type de couvert de tuyau d chappement couvert mural et de toutes les conditions mentionn es sur la carte Les coudes int rieurs ajout s pour les conversions d vent lat rales o...

Страница 17: ...tr e d oiseaux ou d autres animaux La terminaison doit pr senter une r sistance minimale au flux d air vacu et n cessiter peu ou pas de maintenance pour emp cher les obstructions Les vents muraux doiv...

Страница 18: ...ppliquez du ruban adh sive sur TOUS les joints Ins rez et connectez au conduit de la s cheuse MOD LES 27 SEULEMENT VENTIL ES PAR LE BAS OU PAR LES C T S Ins rez le coude faites le pivoter de sorte qu...

Страница 19: ...TIONS DE L APPROVISIONEMENT EN EAU ROBINETS D EAU CHAUDE ET FROIDE Ils doivent tre moins de 42 des branchements de l appareil pour l arriv e d eau Les robinets doivent tre de la tuyauterie du jardin a...

Страница 20: ...e placez un niveau au dessus au fond du couvercle de la laveuse et v rifiez de chaque cot puis v rifiez l avant et l arri re Vissez les pieds de niv lement avant pour assurer que l appareil reste stab...

Отзывы: