GE GUD57EEMTDG Скачать руководство пользователя страница 4

4

Installation Instructions

ELECTRICAL CONNECTION 

INFORMATION FOR ELECTRIC 

DRYERS

Use a new UL-listed 240V 30 amp dryer power 

supply cord with closed ring terminals or spade 

terminals with upturned ends.

Use a UL-listed strain relief.

Disconnect power before making electrical 

connections. 

Connect neutral wire (white or center wire) to center 

terminal.

Ground wire (green or bare wire) must be connected 

to green ground connector. 

Connect remaining two supply wires to remaining 

two terminals.

Securely tighten all electrical connections.

Replace the terminal block cover.

Failure to do so can result in death, fire or electrical 

shock.

For electrical connections using a 

power cord:

ELECTRICAL CONNECTION 

INFORMATION FOR ELECTRIC 

DRYERS

For direct wire connections:

Use 10 gauge solid copper wire.

Use a UL-listed strain relief.

Disconnect power before making electrical 

connections. 

Connect neutral wire (white or center wire) to center 

terminal.

Ground wire (green or bare wire) must be connected 

to green ground connector. 

Connect remaining two supply wires to remaining 

two terminals.

Securely tighten all electrical connections.

Replace the terminal block cover.

Failure to do so can result in death, fire or electrical 

shock.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer:

 This 

appliance must be grounded. In the event of 

a malfunction or breakdown, grounding will 

reduce the risk of electric shock by providing a 

path of least resistance for electric current. This 

appliance uses a cord having an equipment-

grounding conductor and a grounding plug. 

The plug must be plugged into an appropriate 

outlet that is properly installed and grounded in 

accordance with all local codes and ordinances.

Improper connection of the 

equipment-grounding conductor 

can result in a risk of electric shock. Check with a 

qualified electrician, or service representative or 

personnel, if you are in doubt as to whether the 

appliance is properly grounded. 

DO NOT

 modify 

the plug on the power supply cord. If it will not 

fit the outlet, have a proper outlet installed by a 

qualified electrician. 

SAVE THESE INSTRUCTIONS

GROUNDING INSTRUCTIONS

For a permanently connected dryer:

 This 

appliance must be connected to a grounded 

metal, permanent wiring system, or an 

equipment-grounding conductor must be run 

with the circuit conductors and connected to the 

equipment-grounding terminal on the appliance.

Improper connection of the 

equipment-grounding conductor 

can result in a risk of electric shock. Check with a 

qualified electrician, or service representative or 

personnel, if you are in doubt as to whether the 

appliance is properly grounded.

SAVE THESE INSTRUCTIONS

WARNING

Fire Hazard

- Fire Hazard

WARNING

WARNING

Fire Hazard

- Fire Hazard

WARNING

WARNING

WARNING

CONNECTING DRYER USING 4-WIRE 

CONNECTION (MUST BE USED FOR 

MOBILE HOME INSTALLATION)

27” MODELS-CONNECTING 

AN ELECTRIC DRYER

NOTE:

 Since January 1, 1996 the National Electrical 

Code / Canadian Electrical Code requires that new 

constructions use a 4-wire connection to an electric 

dryer. A 4-wire cord must also be used where local 

codes do not permit grounding through the neutral.

This unit has the power cord already installed.

Содержание GUD57EEMTDG

Страница 1: ...ions BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all governing codes and ordinances Insta...

Страница 2: ...ing material carton from the appliance UNPACKING YOUR APPLIANCE 2 Remove the bag containing the washer hoses and parts from tub NOTE With feet set at mid position feet can be adjusted 3 8 Dimension re...

Страница 3: ...other surfaces is 0 either side 0 rear 1 front 1 top Consideration must be given to provide adequate clearance for installation and service Closet doors must be louvered or otherwise ventilated and do...

Страница 4: ...s a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and...

Страница 5: ...nada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance...

Страница 6: ...elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcula...

Страница 7: ...uld require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best...

Страница 8: ...ty hazard 27 MODELS ONLY BOTTOM OR SIDE VENTING For Downward Venting Insert elbow rotate it so that it points downward and connect it to the dryer s internal duct Use only 4 UL approved rigid metal fo...

Страница 9: ...he appliance water inlet hose connections The faucets must be 3 4 garden hose type so inlet hoses can be connected WATER PRESSURE Must be between 20 and 120 pounds per square inch with a maximum unbal...

Страница 10: ...n its final position place a level on top of back part of the washer lid and check it side to side then check front to back Screw the front leveling legs up or down to ensure the appliance is resting...

Страница 11: ...age de l inspecteur lectrique local IMPORTANT Observez toutes les r glementations et ordonnances en vigueur Installez la appareil conform ment aux instructions du fabricant et aux r glementations loca...

Страница 12: ...e D BALLAGE DE VOTRE APPAREIL Enlevez le sac contenant les tuyaux de jonction et les pi ces du bac 3 27 DIMENSIONS NOMINALES DU PRODUIT NOTE Dimensions en pieds correspondant 3 8 S CHEUSES GAZ SEULEME...

Страница 13: ...Il faut veiller procurer le d gagement n cessaire l installation et aux interventions de service Les portes du placard doivent tre perfor es ou autrement ventil es et doivent contenir un minimum de R...

Страница 14: ...risque de choc lectrique en procurant un circuit de moindre r sistance au courant lectrique Cet appareil utilise un cordon dot d un conducteur de mise la terre de l appareillage et d une fiche de mise...

Страница 15: ...bject doivent tre utilis s vitez de faire reposer le conduit sur des objets coupants Pour une meilleure efficacit de s chage 1 Glissez une des extr mit s du conduit par dessus le conduit de sortie de...

Страница 16: ...its du nombre de tours du type de couvert de tuyau d chappement couvert mural et de toutes les conditions mentionn es sur la carte Les coudes int rieurs ajout s pour les conversions d vent lat rales o...

Страница 17: ...tr e d oiseaux ou d autres animaux La terminaison doit pr senter une r sistance minimale au flux d air vacu et n cessiter peu ou pas de maintenance pour emp cher les obstructions Les vents muraux doiv...

Страница 18: ...ppliquez du ruban adh sive sur TOUS les joints Ins rez et connectez au conduit de la s cheuse MOD LES 27 SEULEMENT VENTIL ES PAR LE BAS OU PAR LES C T S Ins rez le coude faites le pivoter de sorte qu...

Страница 19: ...TIONS DE L APPROVISIONEMENT EN EAU ROBINETS D EAU CHAUDE ET FROIDE Ils doivent tre moins de 42 des branchements de l appareil pour l arriv e d eau Les robinets doivent tre de la tuyauterie du jardin a...

Страница 20: ...e placez un niveau au dessus au fond du couvercle de la laveuse et v rifiez de chaque cot puis v rifiez l avant et l arri re Vissez les pieds de niv lement avant pour assurer que l appareil reste stab...

Отзывы: