background image

Installation Instructions

BEFORE YOU BEGIN

‡

 

5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO

duct and replace with UL-listed duct.

‡

 

5HPRYHDQ\OLQWIURPWKHZDOOH[KDXVWRSHQLQJ

Internal 

Duct 

Opening

Wall

Check that exhaust 

hood damper opens 

and closes freely.

STANDARD REAR EXHAUST

We recommend that you install your dryer before 

installing your washer. This will permit direct 

access for easier exhaust connection.

Slide the end of the exhaust duct on the back of the 

dryer and secure with duct tape or a duct clamp.

NOTE:

 We strongly recommend using rigid metal 

exhaust duct. However, if flexible ducting is used it 

must be UL-Listed metal, not plastic. 

‡

 

For straight-line installation, connect the dryer 

exhaust to the wall, using duct tape or a duct 

clamp.

RECOMMENDED CONFIGURATION TO 

MINIMIZE EXHAUST BLOCKAGE

Using duct elbows will prevent duct kinking and 

collapsing.

Transition 

Ducting

14

EXHAUST SYSTEM CHECKLIST

HOOD OR WALL CAP

‡

 

Terminate in a manner to prevent back drafts or entry 

of birds or other wildlife.

‡

 

Termination should present minimal resistance to 

the exhaust airflow and should require little or no 

maintenance to prevent clogging.

‡

 

Wall caps must be installed at least 12” above ground 

level or any other obstruction with the opening 

pointed down.

SEPARATION OF TURNS

‡

 

For best performance, separate all turns by at least 

4 ft. of straight duct, including distance between last 

turn and dampened wall cap. 

SEALING OF JOINTS

‡

 

All joints should be tight to avoid leaks. The male end 

of each section of duct must point away from the 

dryer.

‡

 

Duct joints should be made air- and moisture-tight 

by wrapping the overlapped joints with duct tape or 

aluminum tape.

‡

 

Do not assemble ductwork with any fasteners 

that extend into the duct. These fasteners can 

accumulate lint, creating a potential fire hazard.

‡

 

Horizontal runs should slope down towards the 

outdoors 1/4” per foot.

‡

 

Provide an access for inspection and cleaning of 

the exhaust system, especially at turns and joints. 

Exhaust system shall be inspected and cleaned at 

least once a year.

INSULATION

‡

 

Ductwork that runs through an unheated area or is 

near air conditioning should be insulated to reduce 

condensation and lint buildup.

DUCT TAPE OR

DUCT CLAM

P

DUCT TAPE OR

DUCT CLAM

P

4" METAL DUCT CU

T

TO PROPER LENGTH

EXTERNAL DUCT

OPENING

EXHAUSTING THE DRYER (cont.)

Содержание GTX22EBMKWW

Страница 1: ...re Hazard WARNING Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with fl...

Страница 2: ...brush not included WX14X10007 LintEater Dryer rotary tube brush not included 2 ROUGH IN DIMENSIONS State of California Proposition 65 Warnings The California Safe Drinking Water and Toxic Enforcement...

Страница 3: ...or test gauge connection must be installed immediately upstream of the gas supply connection to the dryer POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord to...

Страница 4: ...the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach...

Страница 5: ...FF position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 10 Adjustable wrenches 2 8 Pipe wrench Flat blade screwdriver Level Slip joint...

Страница 6: ...nector when used must not exceed 3 feet ADJUSTING FOR ELEVATION Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft elevation F...

Страница 7: ...SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at t...

Страница 8: ...NFPA 70 or Canadian Electrical Code CSA C22 1 This appliance must be supplied with 120V 60Hz and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time...

Страница 9: ...2 7 7 50 1 2 Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spri...

Страница 10: ...lure to do so can result in death fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding w...

Страница 11: ...the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 4 ground screw for Step 7 5 Install 3 4 in UL recognized strain relief to power cord en...

Страница 12: ...resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the home exhaust vent using flexible metal IRL...

Страница 13: ...ill be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions a...

Страница 14: ...nce to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed...

Страница 15: ...tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical sup...

Страница 16: ...sert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the joint between the elb...

Страница 17: ...putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DOOR M...

Страница 18: ...er left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow the...

Страница 19: ...holes 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side 5HPRYH the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel...

Страница 20: ...dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 5HPRYH DQG VZDS WKH SODVWLF FDSV DQG WKH hinges 7 5RWDWH WKH RXWHU GRRU GHJU...