Installation Instructions

5

CONNECTING THE DRYER TO HOUSE VENT

RIGID METAL TRANSITION DUCT

•  For best drying performance, a rigid metal transition duct is 

recommended.

‡ 5LJLGPHWDOWUDQVLWLRQVGXFWVUHGXFHWKHULVNRIFUXVKLQJDQG

kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT

‡ ,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHWDO

VHPLULJLGGXFWLQJFDQEHXVHG.LW:;;

‡ 1HYHULQVWDOOÀH[LEOHPHWDOGXFWLQZDOOVFHLOLQJVÀRRUVRURWK

er enclosed spaces.

‡ 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG  IHHW

(2.4m).

• For many applications, installing elbows at both the dryer 

and the wall is highly recommended (see illustrations below). 
Elbows allow the dryer to sit close to the wall without kinking 

DQG RU FUXVKLQJ WKH WUDQVLWLRQ GXFW PD[LPL]LQJ GU\LQJ

performance.

•  Avoid resting the duct on sharp objects.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

• In special installations, it may be necessary to connect the 

GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW
$ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/<
LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG

ducting cannot be used AND where a 4” diameter can be 
maintained throughout the entire length of the transition duct.

‡ ,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO

type) ducts that comply with the “Outline for Clothes Dryer 
Transition Duct Subject 2158A” shall be used.

‡ 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU

other enclosed spaces.

‡ 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKRXOG QRW H[FHHG  IHHW

(2.4m).

•  Avoid resting the duct on sharp objects.
•  For best drying performance:

1. Slide one end of the duct over the clothes dryer outlet pipe.
2. Secure the duct with a clamp.

  With the dryer in its permanent position, extend the duct to 

its full length. Allow 2” of duct to overlap the exhaust pipe. 

&XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKW
DVSRVVLEOHIRUPD[LPXPDLUÀRZ

4. Secure the duct to the exhaust pipe with the other clamp.

DO

ELBOW HIGHLY
RECOMMENDED

ELBOWS HIGHLY
RECOMMENDED

DON’T

DO NOT USE

EXCESSIVE

EXHAUST

LENGTH

DO NOT

CRUSH

FLEXIBLE

EXHAUST

AGAINST

WALL

DO NOT

SIT DRYER

ON FLEXIBLE

EXHAUST

7

BATHROOM OR BEDROOM INSTALLATION

•  The dryer 

MUST

 be vented to the outdoors. See 

EXHAUST 

INFORMATION

VHFWLRQ

•  The installation must conform with local codes or, in the 

absence of local codes, with the 

NATIONAL ELECTRICAL 

CODE, ANSI/NFPA NO. 70.

8

MOBILE OR MANUFACTURED HOME 
INSTALLATION

• Installation 

MUST

 conform to the 

MANUFACTURED HOME 

CONSTRUCTION & SAFETY STANDARD, TITLE 24, PART 32-
80 

or, when such standard is not applicable, with 

AMERICAN 

NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO. 
501B.

• The dryer 

MUST

 be vented to the outdoors with the termination 

securely fastened to the mobile home structure. (See 

EXHAUST 

INFORMATION

VHFWLRQ

• The vent 

MUST NOT

 be terminated beneath a mobile or 

manufactured home.

•  The vent duct material 

MUST BE METAL

.

• Do not use sheet metal screws or other fastening devices 

which extend into the interior of the exhaust vent.

•  See section 2 for electrical connection information.

6

 ALCOVE OR CLOSET INSTALLATION

•  If your dryer is approved for installation in an alcove or closet, 

it will be stated on a label on the dryer back.

• The dryer 

MUST

 be vented to the outdoors. See the 

EXHAUST 

INFORMATION

VHFWLRQV

•  Minimum clearance between dryer cabinet and adjacent walls 

or other surfaces is:

 

0 in. either side

LQIURQWDQGUHDU

‡ 0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV

ceiling, etc. is 52 in.

• Closet doors must be louvered or otherwise ventilated and 

must contain a minimum of 60 sq. in. of open area equally 
distributed. If the closet contains both a washer and a dryer, 
doors must contain a minimum of 120 sq. in. of open area 
equally distributed.

Содержание GTD18ESSJWW

Страница 1: ...ryer see section 1 Step 2 Check and Ensure the Existing External Exhaust is Clean see section 1 and Meets Attached Installation 6SHFL FDWLRQV VHH VHFWLRQ 6WHS 5HPRYH WKH RDP 6KLSSLQJ 3DGV VHH VHFWLRQ Step 4 Move the Dryer to the Desired Location Step 5 Connect the Power Supply see section 2 Step 6 Connect the External Exhaust see section 4 Step 7 Level Your Dryer see section 5 Step 8 Check the Ope...

Страница 2: ...rews of the terminal block marked L1 and L2 B Connect the neutral white line to the center of the terminal block marked N 7 Attach ground wire of power cord with the green ground screw hole above strain relief bracket Tighten DOO WHUPLQDO EORFN VFUHZV VHFXUHO 8 Properly secure power cord to strain relief 9 5HLQVWDOO WKH FRYHU INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FR...

Страница 3: ...ll cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH 4 DIA 4 4 DIA 4 DIA 2 1 2 RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended No of 90º Elbows Rigid Metal Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 60 Feet 45 Feet 35 Feet 25 Feet 15 Feet Use only for sho rt run installations EXHAUST SYSTEM CHECK ...

Страница 4: ...INJURY This clothes dryer must be exhausted to the outdoors Use only 4 rigid metal ducting for the home exhaust duct 8VH RQO µ ULJLG PHWDO RU 8 OLVWHG ÀH LEOH PHWDO VHPL ULJLG RU IRLO W SH GXFW WR FRQQHFW WKH GU HU to the home exhaust duct It must be installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 5 of this manual Do not terminate exhaust in a chim...

Страница 5: ... to its full length Allow 2 of duct to overlap the exhaust pipe XW RȺ DQG UHPRYH H FHVV GXFW HHS WKH GXFW DV VWUDLJKW DV SRVVLEOH IRU PD LPXP DLUÀRZ 4 Secure the duct to the exhaust pipe with the other clamp DO ELBOW HIGHLY RECOMMENDED ELBOWS HIGHLY RECOMMENDED DON T DO NOT USE EXCESSIVE EXHAUST LENGTH DO NOT CRUSH FLEXIBLE EXHAUST AGAINST WALL DO NOT SIT DRYER ON FLEXIBLE EXHAUST 7 BATHROOM OR BE...

Страница 6: ...ap duct tape around joint QVHUW GXFW DVVHPEO HOERZ UVW WKURXJK WKH VLGH opening and connect the elbow to the dryer internal duct CAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct Cut the duct as shown and keep portion A 9 A B FIXING HOLE Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45º using a fl...

Страница 7: ...H VFUHZ VWDUWHG 2 Loosen the top screws from each hinge on the dryer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OUT 5RWDWH WKH GRRU QVHUW WKH GRRU RQ WKH RSSRVLWH side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in ...

Страница 8: ... SODFH 7LJKWHQ E KDQG XQWLO UPO VHDWHG 4 QVHUW WKH OWHU VFUHHQ LQ WKH FRXSOLQJ RI WKH ZDVKHU V LQOHW KRVH I D UXEEHU ÀDW ZDVKHU LV DOUHDG LQ SODFH UHPRYH LW EHIRUH LQVWDOOLQJ WKH OWHU VFUHHQ WWDFK WKLV coupling to one male end of the Y connector Tighten E KDQG XQWLO UPO VHDWHG 5 QVXUH WKH UXEEHU ÀDW ZDVKHU LV LQ SODFH DQG DWWDFK WKH dryer s long inlet hose to the other male end of the Y FRQQHFWRU ...

Отзывы: