Installation Instructions
7
• Apply duct tape as shown on the joint between the
dryer internal duct and the elbow.
ADDING ELBOW FOR EXHAUST
THROUGH BOTTOM OF CABINET
• Insert the elbow through the rear opening and connect
it to the dryer internal duct.
• Apply duct tape on the joint between the dryer internal
duct and elbow, as shown on page 6.
ADDING COVER PLATE TO REAR
OF CABINET (SIDES AND BOTTOM
EXHAUST)
Connect standard metal elbows and ducts to complete
the exhaust system. Cover back opening with a plate
(Kit WE1M454) available from your local service provider.
3ODFHGU\HULQ¿QDOORFDWLRQ
WARNING-
NEVER LEAVE THE BACK
OPENING WITHOUT THE PLATE. (Kit
WE1M454)
PL ATE
(KIT WE1M454)
CHANGING DIRECTION OF DOOR
OPENING
1.
2SHQWKHGRRUDQGUHPRYHWKH¿OOHUSOXJVRSSRVLWHWKH
hinges. With the door completely open, remove the
bottom screws from each hinge on the dryer face. Insert
these screws about half way into the
TOP
holes, for each
KLQJHRQWKHRSSRVLWHVLGHZKHUH\RXUHPRYHGWKH¿OOHU
SOXJV$SSO\¿UPSUHVVXUHWRJHWWKHVFUHZVWDUWHG
2. Loosen the top screws from each hinge on the dryer
face half way. With one hand holding the top of the
door and the other hand holding the bottom, remove
the door from the dryer by lifting it
UP
and
OUT
.
5RWDWH WKH GRRU ,QVHUW WKH GRRU RQ WKH RSSRVLWH
side of the opening by moving the door
IN
and
DOWN
until the top hinge and the bottom hinge are resting on
the top screws inserted in step 1.
4.
5HPRYH WKH UHPDLQLQJ VFUHZV IURP WKH VLGH RI WKH
opening from which the door was removed. With these
screws secure each hinge at the bottom. Tighten the
WZRWRSVFUHZVRQHDFKKLQJH5HLQVHUWWKHSODVWLFSOXJV
on the side from which the door was removed.
REMOVE THE
BOTTOM SCREW
FROM EACH HINGE
ON THE DRYER FACE
LOOSEN THE TOP SCREWS
FROM EACH HINGE ON
THE DRYER FACE
HALF WAY
MOVE THE DOOR IN AND
DOWN UNTIL THE TOP HINGE
AND THE BOTTOM HINGES ARE
RESTING ON THE TOP SREWS
INSERTED IN STEP 1
SECURE EACH HINGE
AT THE BOTTOM AND
TIGHTEN THE TWO TOP
SCREWS OF EACH HINGE
DUCT
TAPE
CAUTIO
N
:
Int
e
rnal duct joints must b
e
s
e
cur
e
d with tap
e
,
oth
e
rwis
e
th
e
y may s
e
parat
e
and caus
e
a
saf
e
ty hazard.
CAUTION:
Internal duct joints must be
secured with tape, otherwise
they may separate and cause
a safety hazard.
11